Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits
  • Gérer vos sites, vos produits et vos contacts au niveau des produits Dell EMC à l’aide de la rubrique Gestion des informations de l’entreprise.

Dell OpenManage Server Administrator Version 7.3 Command Line Interface Guide

Omreport System Events Type Or Omreport Servermodule Events Type

To view the status for components of a specific type, use the omreport system events type=<component name> or omreport servermodule event type=<component name> command. Type:
omreport system events type=fans
or
omreport servermodule events type=fans

This command displays a summary of each component in the system for which events are generated.

The following table displays the events displayed for various component types.
  • NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not available with this release of OpenManage Server Administrator.
Table 1. Valid Parameters Of Omreport System Events Type Or Omreport Servermodule Events Type
name=value pair Description
type=accords Reports events for AC power cords
type=battery Reports events for batteries
type=fanenclosures Reports events for fan enclosures
type=fans Reports events for fans
type=intrusion Reports events for chassis intrusion
type=log Reports events for logs
type=memory Reports events for memory
type=powersupplies Reports events for power supplies
type=redundancy Reports events for redundancy
type=systempower Reports events for system power
type=temps Reports events for temperatures
type=removableflashmedia Reports events for removable flash media
type=volts Reports events for voltages
The following is an example output:
Current SNMP Trap Configuration 
                                 -------
                                 System
                                 -------
                                 Settings
                                 Enable: Informational, Warning, and Critical
                                 Disable: None
                                 -----------
                                 Fans Group
                                 ----------
                                 Settings
                                 Enable: Informational, Warning, and Critical
                                 Disable: None
                                 -----------
                                 Individual Objects
                                 -----------
                                 System Board Fan1 RPM Settings
                                 Index:0
                                 Enable: Informational, Warning, and Critical
                                 Disable: None
                                 System Board Fan2 RPM Settings
                                 Index:1
                                 Enable: Informational, Warning, and Critical
                                 Disable: None
                              

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\