Preskočiť na hlavný obsah
  • Zadávajte objednávky rýchlo a jednoducho
  • Pozrite si svoje objednávky a sledujte priebeh doručenia
  • Vytvorte si zoznam svojich produktov a majte ho vždy poruke
  • Spravujte svoje lokality Dell EMC, produkty a kontaktné informácie na úrovni produktov pomocou Správy informácií o spoločnosti.

Dell PowerEdge T330 Owner's Manual

Hot spare feature

Your system supports the hot spare feature that significantly reduces the power overhead associated with power supply unit (PSU) redundancy.

When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of the load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.

If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU.

The default PSU settings are as follows:
  • If the load on the active PSU is more than 50 percent, then the redundant PSU is switched to the active state.
  • If the load on the active PSU falls below 20 percent, then the redundant PSU is switched to the sleep state.

You can configure the hot spare feature by using the iDRAC settings. For more information about iDRAC settings, see the Integrated Dell Remote Access Controller User’s Guide available at Dell.com/idracmanuals.


Ohodnotiť tento obsah

Presné
Užitočné
Jednoducho pochopiteľné
Bol pre vás tento článok užitočný?
0/3000 characters
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, či vám článok pomohol alebo nie.
  Poznámky nemôžu obsahovať nasledujúce špeciálne znaky: <>()\