iDRAC 8/7 v2.30.30.30 User’s Guide

Enabling or disabling remote RACADM using RACADM

The RACADM remote capability is enabled by default. If disabled, type one of the following command:
  • Using config command: racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 1
  • Using set command: racadm set iDRAC.Racadm.Enable 1
To disable the remote capability, type one of the following command:
  • Using config command: racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 0
  • Using set command: racadm set iDRAC.Racadm.Enable 0
  • NOTE: It is recommended to run these commands on the local system.