Dell OpenManage Deployment Toolkit Version 4.3 Command Line Interface Reference Guide

PDF

Blinking And Unblinking Array Disks

The following table lists the RAIDCFG options, parameters, and pre-defined arguments for blinking and unblinking array disks (hard drives).
  • NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 1. Blinking And Unblinking Array Disks
Mandatory Options and Arguments Optional Parameters Valid Parameters Arguments Description

-ad -ad= ch:targ,ch:targ ,... -ac=blink - c=id or adisk adisk= channel:target , channel:target ,... -ac=blink controllerid= id vdisk=id

NA NA

Blinks the specified physical disks on the specified controller.

Example:

A:>raidcfg -ad -ad=0:1,0:2
                                                ac=blink -c=2
                                                Controller: PERC 6/E
                                                ****** Physical Drive ******
                                                Drive Vendor: SEAGATE
                                                Drive Model: ST336607LC
                                                Drive Location: 0:1:0
                                                Drive Size: 34680 MB
                                                Drive Avail: 0 MB
                                                ****** Physical Drive ******
                                                Drive Vendor: FUJITSU
                                                Drive Model: MAP3367NC
                                                Drive Location: 0:2:0
                                                Drive Size: 34680 MB
                                                Drive Avail: 34680 MB
                                                RAIDCFG Command successful!
                                             

-ad -ad= ch:targ,ch:targ ,... -ac= unblink -c=id or adisk adisk= channel:target , channel:target ,... -ac= unblink controllerid= id vdisk=id

NA NA

Unblinks the specified physical disks on the specified controller.

Example:

A:>raidcfg -ad -ad=0:1,0:2
                                                ac=unblink -c=2
                                                Controller: PERC 6/E
                                                ****** Physical Drive ******
                                                Drive Vendor: SEAGATE
                                                Drive Model: ST336607LC
                                                Drive Location: 0:1:0
                                                Drive Size: 34680 MB
                                                Drive Avail: 0 MB
                                                ****** Physical Drive ******
                                                Drive Vendor: FUJITSU
                                                Drive Model: MAP3367NC
                                                Drive Location: 0:2:0
                                                Drive Size: 34680 MB
                                                Drive Avail: 34680 MB
                                                RAIDCFG Command successful!
                                             