Unsupported Cisco SFP+ Module causes network performance issues

摘要: This article addresses unsupported  Cisco SPF+ modules when used with Broadcom network interface cards.

本文可能採用自動翻譯。如果您對翻譯品質有任何寶貴意見,請使用此頁面底部的表單告訴我們,謝謝。

文章內容


症狀

Event ID 34 will be posted in the System event log.

Log Name: System
Source: ebdrv
Date: 11/28/2013 10:51:15 AM
Event ID: 34
Task Category: None
Level: Warning
Keywords: Classic
User: N/A
Computer: computername.domain.com
Description:
The description for Event ID 34 from source ebdrv cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.
If the event originated on another computer, the display information had to be saved with the event.
The following information was included with the event:
NTPNP_PCI0115
0
CISCO-OEM
SFP-H10GB-CU3M 

 

原因

The unsupported use of a Cisco SFP+ Module SFP-H10GB-CU3M on a Broadcom 57810 NetXtreme II 10 Gigabit NIC can cause network performance issues. Intermittent iSCSI disconnections may occur.

解析度

Replace the SFP+ module with a supported module.