When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution provided, check the technical support contact options.
SLN317175_en_US__1icon Note: Cannot find the information you need? Let us know via the feedback form at the bottom of this article.

 

Cause

Cause has been explained in Resolution section for respective alerts.

Resolution

Alert Text Mapper metadata tier is offline.
Alert ID DATA_PATH_MAPPER_METADATA_TIER_OFFLINE
Description Read and write operations are not available.
Error Code (0x00201901)
Resolution Cause
It can be caused due to issues with cabling and connections between the nodes.

Solution
Check the cabling and connections between the nodes. Also, review any drive or cabling-related alerts and take necessary actions to resolve such issues. If the condition persists, contact Technical Support for assistance.
 
 
Alert Text Mapper Virtual Large Block (VLB) tier is offline.
Alert ID DATA_PATH_MAPPER_VLB_TIER_OFFLINE
Description Read and write operations are not available.
Error Code (0x00201A01)
Resolution Cause
It can be caused due to issues with cabling and connections between the nodes.

Solution
Check the cabling and connections between the nodes. Also, review any drive or cabling-related alerts and take necessary actions to resolve such issues. If the condition persists, contact Technical Support for assistance.
 
 
Alert Text Boot tier offline
Alert ID DATA_PATH_BOOT_TIER_OFFLINE
Description Boot tier metadata is used during system initialization. Data may become unavailable.
Error Code (0x00201801)
Resolution Cause
Issue is caused when both drive from the boot tier are broken which will cause boot tier offline. Another case is boot tier rebuild has not completed because of another drive issue.

Solution
If the condition persists, contact Technical Support for assistance.
 