PowerScale OneFS: Event Notification: Power Supply Failure Detected in Switch xxxx on Int-x Fabric Event ID 200020009

Resumen: OneFS: Event notification: Power supply failure detected in switch xxxx on int-xxx fabric (Event ID 200020009)

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

Event

The following event notification (Event ID 200020009) is received. This event is generated when an internal Ethernet network switch for a cluster has detected a loss of power from one of the power supplies.
Power supply failure detected in switch xxxx on int-xxx fabric

Causa

Details

This event notification is issued when one of the following conditions exists:
  • One of the power supplies in an internal network switch which is not providing power.
  • The power provided from the electrical outlet to the power supply is insufficient.

Resolución

Response

Before you begin troubleshooting the issue, confirm that the event is not related to maintenance on the cluster. After confirming that no maintenance is in progress, proceed with the following troubleshooting.

  1. Determine if the electrical outlet is functioning properly by plugging the power cable into a different electrical outlet.
  2. If the issue is not resolved by using a different outlet, try a replacement power cable.
  3. If power is not restored to the switch, contact Isilon Technical Support for assistance.

Troubleshooting steps:

  1. Check for the switch details to connect to it with commands:
# isi_dump_fabric int-a
# isi_dump_fabric int-b
# python -c "import isi.net.backendmon.util as u; print (u.intuit_switch_addr(\"int-a\")); print (u.intuit_switch_addr(\"int-b\"))"
  1. Connect to the switch and check Power Supply Unit (PSU) status (Make a support case if assistance is required connecting to the switch)
  2. Dell switches are used for backend connection, Check the PSU status using the following command:
# show system

example -
OS10# show system

Node Id              : 1
MAC                  : e8:b5:d0:b8:f6:e9
Number of MACs       : 640
Up Time              : 63 weeks 4 days 22:00:02

...snip 
hit enter for more until you see the PSU

-- Power Supplies --
PSU-ID Status      Type    AirFlow   Fan  Speed(rpm)  Status
----------------------------------------------------------------
1       up          AC      REVERSE   1    13770       up

2       fail
  1.  If the above output shows an issue., then collect the Switch's Serial Number open a Service Request using the Switch's Serial Number to request that a new PSU.

Productos afectados

Isilon Switches
Propiedades del artículo
Número del artículo: 000168299
Tipo de artículo: Solution
Última modificación: 22 ene 2026
Versión:  14
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.