IDPA DP4400: SupportAssist Registration Failure After Upgrade
Summary: After upgrading the IDPA appliance model DP4400 to v2.7.9 (Data Domain Operating System 8.3.1), SupportAssist registration fails with "Access Key and Pin is not valid" due to a mismatch in serial number properties. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Following the upgrade to IDPA version 2.7.9 (DDOS 8.3.1), the Data Domain exhibits the following symptoms:
- System generates an alert indicating the upgrade from Secure Remote Services to SupportAssist failed.
- During SupportAssist registration, the system prompts for an access key, but the supplied key is rejected with the message
Access Key and Pin is not valid for the given device. - Example alert entry:
Id Post Time Severity Class Object Message ------ ---------------------- -------- ----------------- ------ ------------------------------------------------------------- p0-339 2025-09-12 16:27:05 ERROR SystemMaintenance EVT-TLMY-00003: Upgrade from ESRS to SupportAssist failed.

This article only applies to IDPA model DP4400 and other DDVE based Data Domains such as DD3300.
Note: For other IDPA models with a physical Data Domain do not follow this article. Reference article IDPA DP5x00 and DP8x00: SupportAssist Registration Failure After Upgrade to 2.7.9.
Cause
These errors occur as the SupportAssist service expects the Instance Software‑ID (iSWID) value for authentication, but the system uses the appliance serial number, resulting in failure.
The upgrade to IDPA 2.7.9 includes a DDOS version upgrade (8.3.1) that replaces the legacy ConnectEMC/ESRS services with SupportAssist. During this transition, the registration process can fail for DP4400 models because the system captures the wrong identifier.
- The configuration file used by SupportAssist stores the appliance serial number instead of the iSWID. This mismatch causes the registration to reject the generated access key.
- Either of the registry key's
config.connectemc.iswidand orconfig.connectemc.serial_nomay be missing or contain an incorrect value, leading to an invalid access key validation. - The
ESEProperties.jsonfile can also contain the appliance serial number under the serialNumber identifier. This value should contain the iSWID value and not the serial number.
Resolution
Fix:
- Unavailable now but planned for a future release
Workaround:
- Contact Dell Support to apply the required workaround. Reference this article number 000387778 to expedite the resolution.
Affected Products
DD3300 Appliance, PowerProtect DP4400Products
PowerProtect Data Protection Appliance, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwareArticle Properties
Article Number: 000387778
Article Type: Solution
Last Modified: 22 Dec 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.