Dell EMC Unity: Call home alert 14:60284 The disk has reached the end of its service life and needs to be replaced (User Correctable)

Summary: This is an error messages that is generated when the disk has reached the end of its service life. For Certain Drive Part Numbers, please make sure that the Unity OE and drive FW is up to date first before replacing the drive. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Error: The disk has reached the end of its service life and needs to be replaced.

Alert Message ID: 14:60284 ALRT_DISK_EOL_COPY_COMPLETED

Cause

When a disk reaches the end of its service life and user data copy is completed , a call home alert is generated asking to replace the drive.

Resolution

Do not start by replacing the drive. Instead, search the support site by the drive part number and check the related articles on instructions on how to upgrade the Unity OE code and the Drive Firmware to the latest revisions available.

Review DTA article 542005: DTA 542005: Dell EMC Unity: Certain SSD drives are improperly calculating the number of days before End of Life (EOL) (User Correctable)  and KB article 539664: Dell EMC Unity: Certain SSD drives prematurely set EOL-End of Life flags, inducing unnecessary drive replacement (User Correctable)  before doing any replacements to make sure that this is not a false positive.

A drive that is already experiencing the EOL issue can be restored with software commands.

Note: Certain SSDs do not need to be replaced for this issue.

If the Dell EMC Unity array is reporting the dial home 14:60284 for one of the below 38 part numbers,verify that the Unity OE code and the Drive Firmware are updated to the latest release first.
 
5051739 5052379
5052154 5052380
5051740 5052377
5052155 5052378
 
5052556 5052582 5053160
5052557 5052583 5053161
5052558 5052584 5053162
5052559 5052585 5053163
5052576 5052669 5053166
5052577 5052670 5053167
5052578 5053156 5053168
5052579 5053157 5053169
5052580 5053158 5053170
5052581 5053159 5053171

For multiple drive EOL reports for a part number and before taking any action, contact Dell EMC Technical Support or your Authorized Service Representative, and quote this KB article ID. If it is determined that the array is running the latest Unity OE code and the latest drive firmware package or the SSD drive reporting the EOL is not included among the affected part numbers mentioned above, then proceed with normal drive replacement.

CRU VIDEO AVAILABLE!  Dell EMC has produced a short video explaining and demonstrating this change. View the video through the following video:

Affected Products

Dell EMC Unity Family

Products

Dell Unity 300, Dell EMC Unity 300F, Dell EMC Unity 350F, Dell EMC Unity 450F, Dell EMC Unity 500, Dell EMC Unity 500F, Dell EMC Unity 600, Dell EMC Unity 600F, Dell EMC Unity 650F, Dell EMC Unity Family |Dell EMC Unity All Flash , Dell EMC Unity Family, Dell EMC Unity Hybrid ...