DSA-2025-339: Security Update for Dell Avamar Data Store Gen5A Multiple Third-Party Component Vulnerabilities
Shrnutí: Dell Avamar Data Store Gen5A remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Tento článek se vztahuje na
Tento článek se nevztahuje na
Tento článek není vázán na žádný konkrétní produkt.
V tomto článku nejsou uvedeny všechny verze produktu.
Vliv
Critical
Podrobnosti
| Third-party Component | CVEs | More Information |
| Dell PowerEdge Server BIOS | CVE-2024-38796, CVE-2024-28956, CVE-2024-45332, CVE-2024-48012 | DSA-2025-038, DSA-2025-041, DSA-2025-156, DSA-2025-046 |
| Integrated Dell Remote Access Controller (iDRAC) | CVE-2025-26466, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50602, CVE-2024-2961, CVE-2023-6780, CVE-2024-52533, CVE-2023-52340, CVE-2024-42154 | DSA-2025-145. DSA-2025-146, DSA-2024-460 |
Dotčené produkty a náprava
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
Notes:
- This security includes both newly remedied and past vulnerabilities included in this cumulative update.
- Dell recommends upgrading to the latest release/version of your product. To schedule a platform security patch installation or firmware upgrade, please contact Dell Customer Support.
Known Issue:
- Upgrading directly to the August 2025 firmware, which includes BIOS 2.24.0, may fail on systems running BIOS versions prior to 2.12.2, due to compatibility constraints.
Required Action:
- To verify the BIOS version, run the following command in the Avamar console as an admin/root user:
omreport system version
- If the BIOS version is earlier than 2.12.2 contact Dell Customer Support to apply the September 2021 firmware block (AVP: Gen5aSep2021Blk338753.avp) before installing the August 2025 firmware.
Zástupná řešení a opatření pro zmírnění rizik
None
Historie změn
| Revision | Date | Description |
| 1.0 | 2025-09-01 | Initial Release |
| 2.0 | 2025-10-06 | Replaced the NVD generic search link with the PowerEdge and iDrac advisories |
| 3.0 | 2025-10-22 | Major update to include CVE-2024-48012 |
| 4.0 | 2025-12-30 | Updated 'Additional Information' section |
Související informace
Právní upozornění
Dotčené produkty
Avamar, Avamar Data Store, Avamar Data Store Gen5A, Avamar ServerVlastnosti článku
Číslo článku: 000362542
Typ článku: Dell Security Advisory
Poslední úprava: 30 pro 2025
Najděte odpovědi na své otázky od ostatních uživatelů společnosti Dell
Služby podpory
Zkontrolujte, zda se na vaše zařízení vztahují služby podpory.