PowerStore: After an Upgrade of PowerStore to 2.0.x.x or 2.1.x.x, Volumes are Inaccessible to Direct Attached FC Hosts
Shrnutí: After an upgrade of PowerStore to 2.0.x.x or 2.1.x.x, direct attached hosts which have NVMe capable drivers may lose access to all volumes.
Tento článek se vztahuje na
Tento článek se nevztahuje na
Tento článek není vázán na žádný konkrétní produkt.
V tomto článku nejsou uvedeny všechny verze produktu.
Příznaky
A host may lose access to volumes after PowerStore upgrade to the affected version.
Alternatively, if PowerStore was previously upgraded to the affected version without any issues, updating the host drivers to a version supporting NVMe exposes this issue.
Alternatively, if PowerStore was previously upgraded to the affected version without any issues, updating the host drivers to a version supporting NVMe exposes this issue.
Příčina
After the hosts are updated to support NVMe, a second process login (PRLI) can occur from the host following each link up event. This second PRLI is for NVMe transport, and the PowerStore does not handle this second PRLI optimally.
Řešení
This issue is addressed in PowerStoreOS v3.
Workaround:
Disable NVMe support in the driver.
Workaround:
Disable NVMe support in the driver.
- For ESXi hosts, see VMware article 84325
. Summary of VMware article is below:
ESXi using QLogic or Marvel HBA and qlnativefc driver:
esxcfg-module -s 'ql2xnvmesupport=0' qlnativefc
ESXi using Emulex HBA and lpfc driver:
esxcli system module parameters set -m lpfc -p lpfc_enable_fc4_type=1
- For Red Hat hosts, see Red Hat article 3522911
. Summary of Red Hat article is below:
Linux hosts using QLogic or Marvel HBA and qlnativefc driver, add or edit the line below:
vi /etc/modprobe.d/qla2xxx.conf
ql2xnvmeenable=0
Linux hosts using Emulex HBA and lpfc driver, edit the following file and add or edit the line below:
vi /etc/modprobe.d/lpfc.conf
lpfc lpfc_enable_fc4_type=1
NOTE: The hosts must be rebooted after changing the HBA driver configuration.
Dotčené produkty
PowerStore 1000X, PowerStore 1000T, PowerStore 3000X, PowerStore 3000T, PowerStore 5000X, PowerStore 5000T, PowerStore 500T, PowerStore 7000X, PowerStore 7000T, PowerStore 9000X, PowerStore 9000TVlastnosti článku
Číslo článku: 000200588
Typ článku: Solution
Poslední úprava: 14 Jun 2023
Verze: 14
Najděte odpovědi na své otázky od ostatních uživatelů společnosti Dell
Služby podpory
Zkontrolujte, zda se na vaše zařízení vztahují služby podpory.