Dell EMC Networking OS10: Interface Trunk Mode Configuration

Zusammenfassung: How to configure OS10 Trunk Mode on an Interface

Dieser Artikel gilt für Dieser Artikel gilt nicht für Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden. In diesem Artikel werden nicht alle Produktversionen aufgeführt.

Weisungen

Prerequisites:  

  1. Switch has a factory-default configuration with VLANs 10 and 11 configured.
Instructions
Instructions for setting up the management interface network connection:  
  1. Open the CLI using the console or management IP for your S-series switch. 
  2. Log in to the privileged exec mode as default admin credentials. (OS10: user=admin, password=admin).
  3. Show the status of the interfaces, noting the A for ‘access’ mode: 
OS10# show interface status 
Observe Eth 1/1/14 interface, highlighted below. It is in mode A for access.
  1. To modify the switch configuration, run the “configure terminal” command then press enter.
OS10# configure terminal
OS10(config)#
 
  1. To configure the Ethernet 1/1/14 interface enter the “interface ethernet 1/1/14” command:
OS10(config)# interface ethernet 1/1/14
OS10(conf-if-eth1/1/14)#
  1. To change the interface mode to trunk with the “switchport mode trunk” command:
OS10(conf-if-eth1/1/14)# switchport mode trunk
OS10(conf-if-eth1/1/14)#
  1. Configure which trunk vlans will be assigned to the interface with “switchport trunk allowed vlan 10,11”.
OS10(conf-if-eth1/1/14)# switchport trunk allowed vlan 10,11
OS10(conf-if-eth1/1/14)#
  1. Configure which access vlan will be assigned to the port  with command “switchport access vlan 1”.
OS10(conf-if-eth1/1/14)# switchport access vlan 1
OS10(conf-if-eth1/1/14)#
  1. Exit the interface and configuration back to exec mode with the command “end”.
OS10(conf-if-eth1/1/14)# end
OS10#
  1. Verify the configuration changes made on the interface with the command  “show running-configuration interface ethernet 1/1/14”
  1. To verify the changes to the interface with the command “show interface status”. Verify the Mode is now T for trunk. Access VLAN 1 is applied and tagged VLANS 10 and 11 are also assigned.
  1. To save the configuration changes, use the command “write memory”.
OS10# write memory
OS10#


For further assistance, see the Dell EMC SmartFabric OS10 User Guide Release Documentation or reach out to Dell EMC Technical Support.

Weitere Informationen

Refer to this video:

Betroffene Produkte

Enterprise SONiC Distribution
Artikeleigenschaften
Artikelnummer: 000201923
Artikeltyp: How To
Zuletzt geändert: 10 Okt. 2022
Version:  2
Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
Support Services
Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.