ECS: Dial Home - Ref_ID: RepoChunkLevelGC - Symptom Code: 1333

Summary: This is a dial-home detects the RepoChunkLevelGC Alert.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

An ECS has dialed home with the following alert.

<?xml version="1.0" encoding="UTF-8"?>
<ConnectHome SchemaVersion="1.0.8"
    xsi:schemaLocation="/opt/connectemc/schema/ema_ConnectHome108.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
                <Event>
                    <SymptomCode>1333</SymptomCode>
                    <Category>Configuration</Category>
                    <Severity>Warning</Severity>
                    <Status>Unknown</Status>
                    <Component>Object</Component>
                    <ComponentID></ComponentID>
                    <SubComponent>REPO Chunk GC</SubComponent>
                    <SubComponentID></SubComponentID>
                    <CallHome>true</CallHome>
                    <FirstTime>2024-01-29T17:07:36.302Z</FirstTime>
                    <LastTime>2024-01-29T17:07:36.302Z</LastTime>
                    <Count>0</Count>
                    <EventData><![CDATA[]]></EventData>
                    <Description><![CDATA[User garbage collection throughput is too slow to catch up with garbage detection. Please involve ECS engineering.  [Ref_ID : RepoChunkLevelGC]]]></Description>
                </Event>
            </EventList>
        </InternalData>
        <ExternalFiles/>
    </Node>
</ConnectHome>

Cause

The Space Reclamation on user data is too slow. The bottleneck lies on chunk level reclamation. This alert is generated when:

  1. More than 10 TB of full garbage is present.
  2. The difference between the garbage detection rate and the garbage chunk reclaim rate is greater than 100 GB.

This can trigger as a false alert if a recent large deletion has been made. Follow the steps below to determine if so.

Resolution

  1. Connect to one of the nodes in the cluster over a putty session.
  2. Verify Current Sensor Status. 


Command:

# svc_rest_cmd  /vdc/sensor/status/RepoChunkLevelGC

Example:

# svc_rest_cmd  /vdc/sensor/status/RepoChunkLevelGC

svc_rest_cmd 1.0.10
<?xml version="1.0" encoding="UTF-8" standalone="yes"?> svc_rest_cmd  /vdc/sensor/status/RepoChunkLevelGC <SensorStatusList>
  <SensorId>RepoChunkLevelGC</SensorId>
  <ListSensorStatus>
    <SensorStatusRestRep>
      <ContextId>Repo Chunk Level GC</ContextId>
      <CurrentState>OK</CurrentState>
      <NodeId>xxxxxxxxxxxxxxxxxxxxxxxxxxxxx</NodeId>
      <PreviousState>OK</PreviousState>
      <Time>1551118064264</Time>
    </SensorStatusRestRep>
  </ListSensorStatus>
  1. Look for <CurrentState>, if it is set to OK, then error is not active and this is likely a false alert. Ignore the alert, but if it triggers again within the next week then open a service request with Technical Support.

Επηρεαζόμενα προϊόντα

ConnectEMC, ECS Appliance
Ιδιότητες άρθρου
Article Number: 000038651
Article Type: Solution
Τελευταία τροποποίηση: 17 Δεκ 2025
Version:  11
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.