ECS: Ring hjem – Ref_ID: BtreeDiskLevelGC - Symptom Code: 1325
Summary:
Dette er et oppringingshjem som ble introdusert i ECS 3.3 for å oppdage Varsel.
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
Et ECS-system har ringt hjem med følgende varsel.
<?xml version="1.0" encoding="UTF-8"?>
<ConnectHome SchemaVersion="1.0.8"
xsi:schemaLocation="/opt/connectemc/schema/ema_ConnectHome108.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<TransType>10</TransType>
<TransTypeDesc>EventXML</TransTypeDesc>
<TransID>0</TransID>
<Node Status="Unknown" State="Unknown" ID="psnt1">
<Identifier>
<DeviceState>1</DeviceState>
<DeviceStatus>1</DeviceStatus>
<ClarifyID>psnt1</ClarifyID>
<SiteName>UNKNOWN</SiteName>
<Vendor>EMC</Vendor>
<DeviceType>ElasticCloudStorageApp</DeviceType>
<Model>ElasticCloudStorage</Model>
<SerialNumber>psnt1</SerialNumber>
<WWN>ECSQE00077</WWN>
<Platform>platform</Platform>
<OS>SLES</OS>
<OS_VER>12.3</OS_VER>
<UcodeVer>3.3.0.0-4352.834410f</UcodeVer>
<EmbedLevel>2</EmbedLevel>
<InternalMaxSize>512800</InternalMaxSize>
<Comment>Object Alert</Comment>
</Identifier>
<Connection>
<ConnectType>ESRS</ConnectType>
<IPName>sandy-maize.ecs.lab.emc.com</IPName>
<ConnectNum>169.254.197.2</ConnectNum>
<Port>22</Port>
</Connection>
<HeartBeat>
<HBStatus></HBStatus>
<HBState></HBState>
</HeartBeat>
<InternalData>
<FileList/>
<EventList>
<Event>
<SymptomCode>1325</SymptomCode>
<Category>Configuration</Category>
<Severity>Warning</Severity>
<Status>Unknown</Status>
<Component>Object</Component>
<ComponentID></ComponentID>
<SubComponent>BTREE Disk GC</SubComponent>
<SubComponentID></SubComponentID>
<CallHome>true</CallHome>
<FirstTime>2019-01-29T20:05:09.755Z</FirstTime>
<LastTime>2019-01-29T20:05:09.755Z</LastTime>
<Count>0</Count>
<EventData><![CDATA[]]></EventData>
<Description><![CDATA[Capacity free-up throughput is too slow to catch up with system metadata garbage collection. Please involve ECS engineering. [Ref_ID : BtreeDiskLevelGC]]]></Description>
</Event>
</EventList>
</InternalData>
<ExternalFiles/>
</Node>
</ConnectHome>
Cause
Btree GC fungerer sakte på diskkapasitetsfri scene. Dette varselet genereres der det er mer enn 1 TB søppel som venter på sletting, og forskjellen mellom gjenvinningsgraden for søppelfylling og gjenvinningsgraden for søppelkapasitet er større enn 100 GB. Varselet sendes når systemet har vært i denne tilstanden i 7 dager.
Resolution
- Koble til en av nodene i klyngen via en puttøkt.
- Bekreft gjeldende sensorstatus.
Kommando:
svc_rest_cmd /vdc/sensor/status/BtreeDiskLevelGC
# svc_rest_cmd /vdc/sensor/status/BtreeDiskLevelGC
svc_rest_cmd 1.0.10
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<SensorStatusList>
<SensorId>BtreeDiskLevelGCC</SensorId>
<ListSensorStatus>
<SensorStatusRestRep>
<ContextId>BtreeDiskLevelGC</ContextId>
<CurrentState>OK</CurrentState>
<NodeId>47b32995-35fc-4593-8f3c-39c878fb10ad</NodeId>
<PreviousState>OK</PreviousState>
<Time>1551104230509</Time>
</SensorStatusRestRep>
</ListSensorStatus>
- Se etter <CurrentState>, hvis den er satt til OK, er feilen ikke aktiv, og dette er sannsynligvis et falskt varsel. Ignorer varselet, men hvis det aktiveres på nytt i løpet av neste uke, åpner du en serviceforespørsel med teknisk støtte
Επηρεαζόμενα προϊόντα
ConnectEMC, ECS ApplianceΙδιότητες άρθρου
Article Number: 000038657
Article Type: Solution
Τελευταία τροποποίηση: 17 Δεκ 2025
Version: 8
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.