Data Domain: Disk Rescan Procedure
Summary: This article describes how to perform the disk rescan procedure on a Dell Data Domain system. The rescan operation manually polls all disk drives, forcing the system to reevaluate their state. While DDOS typically performs automatic scans, a manual rescan may be necessary if a replacement disk is not recognized. ...
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
Warning: This procedure applies only to single disk absent alerts. Do not use this method if multiple disks are reporting absent, as this may risk data loss.
Applies to:
- All Data Domain systems
- All software Versions
Symptoms
- Autosupport alerts such as:
Err Code: STORAGE-00002 | STORAGE00002
Enclosure disk is absent and should be replaced
Disk in Absent State
- Disk not recognized after replacement
- Unable to bring the disk into a usable state (in-use or spare)
Cause
Sometimes, DDOS may fail to detect a newly inserted disk due to:
- Background processes interfering with disk discovery
- Disk replaced too quickly before the system completed its internal checks
- Transient hardware or communication issues
Resolution
Follow these steps to perform a disk rescan:
-
Initial Rescan
At the CLI prompt, run:-
disk rescan -
Wait for the command prompt to return.
- If the disk is still reported as 'Absent', follow the steps below.
-
-
Remove the Disk Drive
Carefully remove the disk in question. -
Inspect the Disk
- Check terminal connectors for debris or bent/damaged pins.
- If pins are damaged, replace the disk.
-
Wait for Detection Timeout
- Allow 2 minutes for the SAS backplane to register the removal.
-
Trigger Second Rescan
At the CLI prompt, run:-
disk rescan -
Wait for the command prompt to return.
-
-
Reinsert the Disk
- Firmly reinsert the disk into its original slot.
- Wait another 2 minutes for DDOS to detect the change.
-
Verify Disk State
- Run
disk show hardwareordisk show stateto confirm the disk is now listed as in-use or spare.
- Run
Επηρεαζόμενα προϊόντα
Data DomainΠροϊόντα
Data DomainΙδιότητες άρθρου
Article Number: 000045237
Article Type: Solution
Τελευταία τροποποίηση: 07 Οκτ 2025
Version: 3
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.