Connectrix B-Series: Device Logging In as a Loopback
Summary: This article explains why a Connectrix B-Series switch port may detect an attached HBA or storage device as a loopback port and how to troubleshoot the condition.
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
An HBA or storage device automatically configures as a loopback port on a Connectrix B-Series switch.
Cause
This could be caused by the controller configuration on the HBA or storage device.
Resolution
Check whether the end device is configured for Fibre Channel Arbitrated Loop (FC-AL). Also check the integrity of the SFP and cable. Then reset the port as follows:
portcfgpersistentdisableportcfgdefaultportcfgpersistentenable
If the status of the port is still loopback after performing the above, move the cable to a free port. If the issue follows the cable, it is likely an issue with the connected device. Further troubleshooting must be performed at that end.