PowerStore Alerts: Node and Host Management Port Group Alerts

Summary: This article discusses about Node and Host Management Port Group (PG) Alerts.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.
SLN322737_en_US__1icon Note: Cannot find the information that you need? Let us know using the feedback form at the bottom of this article.

Cause

Cause has been mentioned in the Resolution section for respective alerts.

Resolution

Alert ID ONV_NODE_MGMT_PG_PRESENCE_NOT_FOUND
Alert Text Unable to find a system VM management port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name).
Error Code (0x01803E02)
Description This alert is raised when system VM management port group presence on a distributed virtual switch is not found.
Resolution Solution
Configure a system VM management port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the PowerStore Virtualization Infrastructure Guide. If the issue persists, contact Technical Support for assistance.
 
 
Alert ID ONV_NODE_MGMT_PG_VLAN_STATE_INVALID
Alert Text The system VM management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id).
Error Code (0x01803F03)
Description This alert is raised when the state of VLAN configuration on a system VM management port group of a distributed virtual switch is invalid.
Resolution Solution
Configure VLAN ID in vCenter.
 
 
Alert ID ONV_HOST_MGMT_PG_PRESENCE_NOT_FOUND
Alert Text Unable to find an ESXi host management port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name).
Error Code (0x01804002)
Description This alert is raised when ESXi host management port group presence on a distributed virtual switch is not found.
Resolution Solution
Configure an ESXi host management port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the PowerStore Virtualization Infrastructure Guide. If the issue persists, contact Technical Support for assistance.
 
 
Alert ID ONV_HOST_MGMT_PG_VLAN_STATE_INVALID
Alert Text The ESXi host management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id).
Error Code (0x01804103)
Description This alert is raised when the state of a VLAN configuration on an ESXi host management port group of a distributed virtual switch is invalid.
Resolution Solution
Configure VLAN ID in vCenter.