Symptoms
When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.
Note: Cannot find the information that you need? Let us know using the feedback form at the bottom of this article.
Note: Cannot find the information that you need? Let us know using the feedback form at the bottom of this article.
Cause
Cause has been mentioned in the Resolution section for respective alerts.
Resolution
| Alert ID | ONV_NODE_MGMT_PG_PRESENCE_NOT_FOUND |
| Alert Text | Unable to find a system VM management port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name). |
| Error Code | (0x01803E02) |
| Description | This alert is raised when system VM management port group presence on a distributed virtual switch is not found. |
| Resolution | Solution Configure a system VM management port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the PowerStore Virtualization Infrastructure Guide. If the issue persists, contact Technical Support for assistance. |
| Alert ID | ONV_NODE_MGMT_PG_VLAN_STATE_INVALID |
| Alert Text | The system VM management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id). |
| Error Code | (0x01803F03) |
| Description | This alert is raised when the state of VLAN configuration on a system VM management port group of a distributed virtual switch is invalid. |
| Resolution | Solution Configure VLAN ID in vCenter. |
| Alert ID | ONV_HOST_MGMT_PG_PRESENCE_NOT_FOUND |
| Alert Text | Unable to find an ESXi host management port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name). |
| Error Code | (0x01804002) |
| Description | This alert is raised when ESXi host management port group presence on a distributed virtual switch is not found. |
| Resolution | Solution Configure an ESXi host management port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the PowerStore Virtualization Infrastructure Guide. If the issue persists, contact Technical Support for assistance. |
| Alert ID | ONV_HOST_MGMT_PG_VLAN_STATE_INVALID |
| Alert Text | The ESXi host management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id). |
| Error Code | (0x01804103) |
| Description | This alert is raised when the state of a VLAN configuration on an ESXi host management port group of a distributed virtual switch is invalid. |
| Resolution | Solution Configure VLAN ID in vCenter. |
Επηρεαζόμενα προϊόντα