Data Domain: DD3300: Etter at du har skiftet ut en disk, fortsetter diskvarselet

Summary: Etter en diskutskifting oppdateres ikke den nye diskinformasjonen på Data Domain Operating System (DDOS), og varselet blir stående.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

Merk: DD3300 kjører en modifisert versjon av Data Domain (DD) Virtual Edition (DDVE)-programvaren.
 

Innenfor Data Domain-operativsystemet (DDOS):

1. Den nye diskinformasjonen oppdateres ikke:
# disk show hardware-detailed
Disk   Slot        Manufacturer/Model   Firmware   Serial No.         Capacity   Type       State  
       (pci/idx)                                                                                   
----   ---------   ------------------   --------   --------------   ----------   --------   --------
1.1    0           ST4000NM017A         CSJ7       WJG12JG9           3.64 TiB   SAS        In Use 
1.2    1           ST4000NM017A         CSJ7       WJG18M5C           3.64 TiB   SAS        In Use 
1.3    2           ST4000NM017A         CSJ7       WJG12HZN           3.64 TiB   SAS        In Use 
1.4    3           ST4000NM017A         CSJ7       WJG18M6X           3.64 TiB   SAS        In Use 
1.5    4           ST4000NM017A         CSJ7       WJG19CGX           3.64 TiB   SAS        In Use 
1.6    5           ST4000NM017A         CSJ7       WJG17136           3.64 TiB   SAS        In Use 
1.7    6           ST4000NM017A         CSJ7       WJG19B57           3.64 TiB   SAS        In Use 
1.8    7           ST4000NM017A         CSJ7       WJG19DQ3           3.64 TiB   SAS        In Use 
1.9    8           ST4000NM017A         CSJ7       WJG17YCG           3.64 TiB   SAS        In Use 
1.10   9           ST4000NM017A         CSJ7       WJG18MK0           3.64 TiB   SAS        Unknown  <<-- Old serial number
1.11   10          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.12   11          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.13   12          MZ7LH480HBHQ0D3      HG57       S5YJNE0N810008   447.13 GiB   SATA-SSD   Non-RAID 
 
2. Diskvarselet slettes ikke:
Current Alerts
--------------
Id      Post Time                  Severity   Class             Object                                         Message                                                                    
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
p0-24   Thu Dec 30 05:00:57 2021   CRITICAL   HardwareFailure   Enclosure=1:Disk=10:Cause=NA                   EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.  
p0-25   Thu Dec 30 11:11:29 2021   WARNING    HardwareFailure   Enclosure=1:Disk=10:Cause=Predictive failure   EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
There are 2 active alerts.
 

I Integrated Dell Remote Access Controller (iDRAC):

Hendelsesloggen KAN vise oppdagelsen av diskutskiftingen. Maskinvareendringen overføres imidlertid ikke til DDVE.
 
iDRAC-hendelser:
Timestamp           Record              Message
2022-02-04 11:47:06      7              The watchdog timer expired.
2022-01-07 22:12:46      6              Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17      5              Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16      4              Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02      3              Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25      2              The watchdog timer expired.
 

På ESXi:

Informasjonen i PTAgent som lytter til iDRAC, inneholder ingen bevis for ødelagt kommunikasjon:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 

Cause

IDRAC oppdaterer ikke lagringsinformasjonen.
 
Forventningen til iDRAC har alltid vært at det skal kunne oppdatere lagringsbeholdningen og oppgi den nyeste og korrekte diskinformasjonen til PTAgent (på ESXi) og vulcanmon (på DDOS) når en disk fjernes eller settes inn.
 
Noen ganger oppdateres ikke iDRAC, og iDRAC må tilbakestilles manuelt.

Resolution

  1. Tilbakestill iDRAC på nett ved hjelp av brukergrensesnittet.
  2. Utfør en kald tilbakestilling (aka "loppeavløp") per BMC Reset (aka Flea Drain) Prosedyre.
  3. Kontroller og bekreft at relaterte varsler er slettet, og at diskmaskinvaren vises som forventet.

Επηρεαζόμενα προϊόντα

Data Domain, DD3300 Appliance
Ιδιότητες άρθρου
Article Number: 000197080
Article Type: Solution
Τελευταία τροποποίηση: 18 Ιουν 2026
Version:  5
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.