Data Domain: DD3300: När du har bytt ut en disk kvarstår diskvarningen
Summary: Efter ett diskbyte uppdateras inte informationen om den nya disken i Data Domain-operativsystemet (DDOS) och varningen kvarstår.
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
Obs! DD3300 kör en modifierad version av programvaran Data Domain (DD) Virtual Edition (DDVE).
Inom Data Domain-operativsystemet (DDOS):
1. Den nya diskinformationen uppdateras inte:
# disk show hardware-detailed
Disk Slot Manufacturer/Model Firmware Serial No. Capacity Type State
(pci/idx)
---- --------- ------------------ -------- -------------- ---------- -------- --------
1.1 0 ST4000NM017A CSJ7 WJG12JG9 3.64 TiB SAS In Use
1.2 1 ST4000NM017A CSJ7 WJG18M5C 3.64 TiB SAS In Use
1.3 2 ST4000NM017A CSJ7 WJG12HZN 3.64 TiB SAS In Use
1.4 3 ST4000NM017A CSJ7 WJG18M6X 3.64 TiB SAS In Use
1.5 4 ST4000NM017A CSJ7 WJG19CGX 3.64 TiB SAS In Use
1.6 5 ST4000NM017A CSJ7 WJG17136 3.64 TiB SAS In Use
1.7 6 ST4000NM017A CSJ7 WJG19B57 3.64 TiB SAS In Use
1.8 7 ST4000NM017A CSJ7 WJG19DQ3 3.64 TiB SAS In Use
1.9 8 ST4000NM017A CSJ7 WJG17YCG 3.64 TiB SAS In Use
1.10 9 ST4000NM017A CSJ7 WJG18MK0 3.64 TiB SAS Unknown <<-- Old serial number
1.11 10 (absent) (absent) (absent) (absent) (absent) Absent
1.12 11 (absent) (absent) (absent) (absent) (absent) Absent
1.13 12 MZ7LH480HBHQ0D3 HG57 S5YJNE0N810008 447.13 GiB SATA-SSD Non-RAID
2. Diskvarningen rensas inte:
Current Alerts
--------------
Id Post Time Severity Class Object Message
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
p0-24 Thu Dec 30 05:00:57 2021 CRITICAL HardwareFailure Enclosure=1:Disk=10:Cause=NA EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.
p0-25 Thu Dec 30 11:11:29 2021 WARNING HardwareFailure Enclosure=1:Disk=10:Cause=Predictive failure EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
There are 2 active alerts.
I Integrated Dell Remote Access Controller (iDRAC):
Händelseloggen KAN visa upptäckten av diskbytesåtgärden. Maskinvaruändringen överförs dock inte till DDVE.
iDRAC-evenemang:
Timestamp Record Message
2022-02-04 11:47:06 7 The watchdog timer expired.
2022-01-07 22:12:46 6 Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17 5 Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16 4 Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02 3 Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25 2 The watchdog timer expired.
På ESXi:
Informationen
PTAgent som lyssnar på iDRAC inte innehåller några bevis på den brutna kommunikationen:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy Cause
iDRAC uppdaterar inte sin lagringsinformation.
Förväntningen på iDRAC har alltid varit att det ska gå att uppdatera lagringsinventeringen och tillhandahålla den senaste och korrekta diskinformationen till
PTAgent (på ESXi) och vulcanmon (på DDOS) när en disk tas bort eller sätts i.
Ibland uppdateras inte iDRAC och iDRAC måste återställas manuellt.
Resolution
- Återställ iDRAC online med hjälp av användargränssnittet.
- Utför en kall återställning (även kallat "loppdränage") enligt BMC-återställningsproceduren (även kallat loppdränage).
- Kontrollera och bekräfta att relaterade aviseringar har rensats och att diskmaskinvaran visas som förväntat.