Dell Networking OS10: Basic Switch Management Configuration

Summary: How to configure OS10 basic switch management.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Instructions

Prerequisites:

  • The switch has a factory-default configuration.

Instructions

Instructions for setting up the management interface network connection with a user-defined IP address:

  1. Open a CLI session using the console for the S-series switch.

  2. Log in to the privileged exec mode as default admin credentials. (OS10: user=admin, password=admin).

  3. Show the running configuration of the management interface:

    OS10# show running-configuration interface mgmt 1/1/1
    
    interface mgmt1/1/1
     no shutdown
     ip address dhcp
     ipv6 address autoconfig
  4. To modify the switch configuration, run the configure terminal command then press Enter.

    OS10# configure terminal
    OS10(config)#
  5. To configure the management interface:

    OS10(config)# interface mgmt 1/1/1
    OS10(conf-if-ma-1/1/1)#
  6. To stop the management interface DHCP process use:

    OS10(conf-if-ma-1/1/1)# no ip address dhcp
  7. Configure a static IP address on the management interface with: ip address A.B.C.D/mask

    OS10(conf-if-ma-1/1/1)# ip address 1.1.1.1/24
    OS10(conf-if-ma-1/1/1)# <165>1 2022-07-08T16:46:15.515380+00:00 S4148-140 dn_alm 801 - - Node.1-Unit.1:PRI [event], Dell EMC (OS10) %IP_ADDRESS_ADD: IP Address add is successful. IP 1.1.1.1/24 in VRF:default added successfully
  8. Exit the management interface configuration mode to move to config mode:

    OS10(conf-if-ma-1/1/1)# exit
    OS10(config)#
    OS10(config)#
  9. In config mode, create a default management route: management route A.B.C.D/mask(destination prefix) A.B.C.D(forwarding router’s address)

    S4148-140(config)# management route 0.0.0.0/0 1.1.1.2
  10. Exit config mode to exec mode with:

    S4148-140(config)# end
    S4148-140#
  11. In exec mode, verify that the management interface configuration is correct:

    OS10# show running-configuration interface mgmt 1/1/1
    !
    interface mgmt1/1/1
     no shutdown
     no ip address dhcp
     ip address 1.1.1.1/24
     ipv6 address autoconfig
    OS10#
  12. Show that the management route is present and correct:

    OS10# show running-configuration management-route
    !
    management route 0.0.0.0/0 1.1.1.2
    OS10#

Instructions for setting up an admin level user:

  1. Open the CLI using the console or management IP for the S-series switch.

  2. Log in to the privileged exec mode as default credentials. (OS10: user=admin, password=admin).

  3. To modify the switch configuration, run the configure terminal command then press Enter.

    OS10# configure terminal
    OS10(config)#
  4. Configure a username 'test' and password with sysadmin privileges: username <string> password <string> role <sysadmin/netoperator/secadmin/netadmin>

    OS10(config)#username test password P@ssw0rd!123 role sysadmin
  5. Exit config mode to exec mode:

    OS10(config)# end
    OS10#
  6. Verify the users configured on the system:

    OS10# show running-configuration users
    username test password **** role sysadmin priv-lvl 15
    OS10#
  7. Save the running configuration to startup configuration:

    OS10# write memory

For further assistance, see the Dell SmartFabric OS10 User Guide Release Documentation or reach out to Dell Technologies Technical Support.

 

Additional Information

See this video:

 

Ιδιότητες άρθρου
Article Number: 000201924
Article Type: How To
Τελευταία τροποποίηση: 14 Μαΐ 2026
Version:  4
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.