Data Domain: Changing Bond Type with LACP Switch configuration Disables Interfaces
Summary: On intel network cards changing virtual bond to another bonding type while switch is still LACP triggers a possible driver bonding issue and disables all interfaces on all cards.
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
Loss of connectivity on all interfaces
kern.info logs show the following:
ice 0000:1f:00.0: Error clearing VSI prune list
ice 0000:af:00.2: Failed to remove RDMA switch rule
ice 0000:ae:00.2: ethXx: Attempt to be Primary, but incompatible state. 1Cause
Changing a virtual bond through the DD UI or CLI from LACP to another type while switch side is configured for LACP disables all interfaces.
The root cause is a known class of rare ice driver issue on intel network cards.
Resolution
Undo the change by iDRAC and a reboot to restore connectivity.
If iDRAC is not available, then direct serial access is needed.
Engineering PowerEdge and Intel team are working on a permanent fix.