VNX Storage Processor reports event 71678001 ESP_ERROR_SPS_REMOVED

Summary: Event 71678001 reported for either a Standby Power Supply or a Battery Backup Unit.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Standby Power Supply (SPS) failures can potentially cause Write Cache to become disabled.

The array reports event codes such as the following:

71678001 ESP_ERROR_SPS_REMOVED
71678001 BBUA has been Removed

 

Cause

The event is for either the SPS or the Battery Backup Unit Assembly (BBUA), depending on the array type.
This event may also be reported as part of the SP boot sequence, which is not a fault if it is followed by events such as the following:

espkg            71670002 BBUA Inserted.
espkg            71670003 BBUA State Changed (TestStarted to TestCompleted).
espkg            71670003 BBUA State Changed (NotBatteryReady to BatteryReady).
espkg            71670003 BBUA State Changed (Testing to BatteryReady).

 

Resolution

SPcollects should be gathered and checked to see if the SPS or BBU is still faulted.
Determine if the SPS/BBU was intentionally removed or if there is some problem such as a loose cable or incorrectly inserted component.

 