Connectrix Cisco: "Security alert:SRVNAME_RTD_MONITOR-2-SECURITY_ALERT: SECURITY-WARNING: ASLR ENTROPY INSUFFICIENT" received in logging log
Summary: This security alert is periodically seen in the show logging log output due to the memory randomization check failed.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Error in the show logging log:"%SRVNAME_RTD_MONITOR-2-SECURITY_ALERT: SECURITY-WARNING: ASLR ENTROPY INSUFFICIENT "
Cause
- The above message indicates a periodic memory randomization check failed.
- When such checks fail, there is no impact to the production traffic.
- If this message appears only once, it can be safely ignored.
- If there is repetitive behavior, this switch needs attention.
Resolution
1. Check the output of the command:
2. Take a note of the Entropy range.
3. Any range from 8-19 is considered "Good" and can be ignored.
4. Any range below 8 is bad and must involve Cisco TAC to verify the switch.
show security system stateExample:
MDS9710-s1fA-sw1# show security system state XSPACE: Non-Executable stack : Yes Non-Executable heap : Yes Non-Writable text : Yes ASLR: randomize_va_space : 2 (Enabled) Randomization Self-test : Pass CVE-offset2lib Test : Pass Randomization Entropy : 8-19 stack bits : 19 heap bits : 13 text bits : 8 bss bits : 8 data bits : 8 anon map bits : 9 thread stack bits : 9 OSC: Version: 3.0.0 SafeC: Version: 3.0.1a
2. Take a note of the Entropy range.
3. Any range from 8-19 is considered "Good" and can be ignored.
4. Any range below 8 is bad and must involve Cisco TAC to verify the switch.
Affected Products
Connectrix MDS-Series Firmware, Connectrix MDS-Series HardwareArticle Properties
Article Number: 000212067
Article Type: Solution
Last Modified: 30 May 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.