Connectrix B-Series: DS-65xx-processorn omstartad – programvarufel: Kernel Panic
Summary: DS-65xx växlar mjukvarupanik
Symptoms
DS-65xx startar oväntat om en gång och är sedan online igen utan problem.
switchType: 109.1
switchState: Online
Fabric OS: v7.4.1b
Drifttid:
03:18:40 upp 27 min, 1 användare, belastningsgenomsnitt: 1,09, 0,60, 0,30
errdump -a:
2016/10/10-02:51:17:200273, [HAM-1004], 3037/451, CHASSI, INFO, DFW3-2830130-793765-B, processor omstartad – Programvarufel:Kernel Panic., reboot.c, rad: 113, comp:hamd, ltime:2016/10/10-02:51:13:175020
2016/10/10-02:51:20:119799, [EM-5012], 3052/0, CHASSI, INFO, DFW3-2830130-793765-B, start emd FSS_RECOV_COLD, emfss.c, rad: 437, comp:emd, ltime:2016/10/10-02:51:20:116608
2016/10/10-02:51:20:632805, [DIAG-6004], 3055/0, CHASSI, INFO, DFW3-2830130-793765-B, test_thread: tname porttestd Anropa fcn – PID: 1314, parameter.c, rad: 1448, comp:insmod, ltime:2016/10/10-02:51:20:630948
2016/10/10-02:51:26:438892, [EM-5012], 3056/0, CHASSI, INFO, DFW3-2830130-793765-B, slut emd FSS_RECOV_ACTIVE (kall), emfss.c, rad: 522, comp:emd, ltime:2016/10/10-02:51:26:433133
Cause
I SUPPORTSHOW-filen genereras utdata från Core-filen.
Omkopplaren hade en machine check/i-cache parity error med flera problematiska felkoder för DDR SDRAM (Double Date Rate Synchronous Dynamic Random Access Memory) enligt nedan.
PDSHOW:
______________________********________________________
* Fil :/core_files/panic/core.pd20161010024344 *
* AVSNITT:CONSOLE_LOG *
-----------------------********------------------------
============= SLUTET AV HUVUDET OCH BÖRJAN AV SVANSEN
=========Maskinkontroll i kärnläge.
Cache-paritetsfel
PLB41-domare: DDR SDRAM-minne: DDR0_00=0x0000190a DDR SDRAM-minne: DDR0_01=0x01000000 DDR SDRAM-minne: DDR0_31=0x00000000 DDR SDRAM-minne: DDR0_32=0x00000000 DDR SDRAM-minne: DDR0_33=0x00000000 DDR SDRAM-minne: DDR0_34=0x00000008 DDR SDRAM-minne: DDR0_35=0x00000000 DDR SDRAM-minne: DDR0_36=0xffffffff DDR SDRAM-minne: DDR0_37=0xffffffef DDR SDRAM-minne: DDR0_38=0x00000028 DDR SDRAM-minne: DDR0_39=0x00000000 DDR SDRAM-minne: DDR0_40=0x00000000 DDR SDRAM-minne: DDR0_41=0x00000000
============= ÄNDEN AV SVANSEN =========================
Resolution
Vanligtvis indikerar den här typen av fel ett hårdvaruproblem.
Lösning: Fortsätt att övervaka switchen så att problemet upprepas.
Reparera: Sätt tillbaka strömbrytaren.
Additional Information
Switchen kör FOS 7.4.1b.