PowerStore: Landing Page for In Market off-release System Health Checks

Summary: Occasionally health checks should be added after the PowerStoreOS is released. These health checks are supplied by the thin package mechanism, and identify various known issues in the PowerStore cluster. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Background

Occasionally new issues are found following the release of a PowerStoreOS which are not detected by the OS's integrated health checks and alerts features. The Heath Check thin package feature is used to deliver new health checks to an installed PowerStoreOS.

The Health check package contains health checks that are performed prior to a Non-Disruptive Upgrade (NDU). The package also includes general system health checks that are invoked, on demand, from the PowerStore Manager (Monitoring > System Checks > Run System Check).

The health check package must be uploaded to the PowerStore cluster and then installed.

IMPORTANT
For detailed instructions on installing and using the health check package, see one of these KB articles:

Table of Contents

Health Check package for 4.2.x, 4.3.x, and 4.4.x.

The table below lists the health checks that are in the PowerStore-health_check-4.4.0.0-2720358-retail.tgz.bin Health Check thin package. The package is compatible with PowerStoreOS version 4.2.x, 4.3.x, and 4.4.x only.

Refer to PowerStore: RxDefinitions Issues Landing Page for information about tests that are included with this package.

Pre-Upgrade Health Checks (PUHC)

LEGEND: In this table, the symbol * indicates checks introduced or enhanced in this most recent Health Check thin package.

Table 1. PowerStore-health_check-4.4.0.0-2720358-retail.tgz.bin Health Checks

Test name Description KB Article
PS Redundancy Detects non-redundant power supplies PowerStore: Pre-Upgrade Health Check (PUHC) detects non-redundant power supply
scheduled_vm_snapshot Detects if there are any VM scheduled snapshots in progress PowerStore: Pre-Upgrade Health Check (PUHC) checks if all snapshot commands are all in completed state.
ens24_drive_missing_path_check Checks the system for non-redundant NVMe drive paths that are either failed or missing PowerStore: Pre-Upgrade Health Check (PUHC) to detect non-redundant NVMe drive paths
incomplete_commands_check PUHC detects incomplete Control Path (CP) commands that are not in the approved list of commands allowed during NDU PowerStore: Pre upgrade health check (PUHC) to detect incomplete CP commands
unsupported_drive_check PUHC detects a system with drives not covered by DriveDB.json v0.6.6.0 PowerStore Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0
nvram_full_fips_check Detect NVRAM disk's full FIPS is not set correctly PowerStore: System Health Check and/or Pre-Upgrade Health Check 3.x/4.x | Replacement of NVMe NVRAM disks may incorrectly raise FIPS alerts
kernel_slab_check Detect if any node has slab allocation over the skbuff_fclone_cache limit PowerStore: Health Checks Detect if any Node has Slab Allocation Over the skbuff_fclone_cache Limit
duplicate_or_inconsistent_ntp_addresses Detect duplicate or inconsistent NTP configuration PowerStore: Pre-Upgrade Health Check (PUHC) to identify duplicate NTP entries
off_release_asymmetric_netdevice_check * Detect asymmetrical net device configuration PowerStore: Pre-Upgrade Health Check (PUHC) to Identify Asymmetric NetDevice Configuration
user_db_fewer_records * Detects if necessary user.db entries are lost or different between the nodes of the affected appliance PowerStore: Pre upgrade health check (PUHC) to detect if necessary user.db entries are lost, or different between nodes

System Checks

LEGEND: In this table, the symbol * indicates checks introduced/enhanced in this most recent Health Check thin package.

Table 2. PowerStore-health_check-4.4.0.0-2720358-retail.tgz.bin System Checks

Test name Description KB Article
four_port_iom_state_check Detects if 4PortCard is incorrectly set to fru_is_not_in_use PowerStore: System Health Check detects 4PortCard Incorrectly Set to fru_is_not_in_use
indus_encryption_offset_check Detects drive invalid encryption band location for NVMe expansion enclosures PowerStore: System Check detects drive invalid encryption band location for ENS24 enclosure
unfinished_ndu_check Detects the existence of an unfinished upgrade PowerStore: System Health Check has detected remnants of failed NDU commits
indus_drive_paths_check Detects unstable paths to ENS24 NVMe expansion enclosure PowerStore: System Health Check detects unstable paths to the ENS24 NVMe expansion enclosure.
cpu_ierr_check Checks for CPU internal error PowerStore: System Health Checks detects an issue in the CPU IERR Check
active_system_alert_check Detects active Major and Critical alerts PowerStore: Active alerts detected by health checks
cyc_node_space_check Detects node's /cyc_node directory has insufficient space PowerStore: System Health Checks Detects Lack of Space in cyc_node
time_skew_check Detects unsupported large time skew PowerStore: Health Checks detects high time skew on Nodes and BMC
component_sn_check Detects inconsistent serial number for BBU or PSU PowerStore: System Health Checks detects component Serial Numbers are not consistent: Component SN Check
invalid_vg_uuid_check Detects if a volume group with no member in Control Path (CP) exists PowerStore: Health Checks detect if a volume group with no members exists
kernel_slab_check Detect if any node has slab allocation over the skbuff_fclone_cache limit PowerStore: Health Checks Detect if any Node has Slab Allocation Over the skbuff_fclone_cache Limit
dp_mem_allocation_override_check Detects wrong Data Path (DP) memory settings PowerStore: System Health Checks detects wrong Data Path memory settings
unsupported_drive_check Detects a system with drives not covered by DriveDB.json v0.6.6.0 PowerStore Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0

Health Check package for 4.0.x and 4.1.x

The table below lists the health checks that are in the PowerStore-health_check-4.1.0.0-2720511-retail.tgz.bin Health Check thin package. The package is compatible with PowerStoreOS versions 4.0.x and 4.1.x only.

When using this Health Check package, also upload and install the RxDefinitions package. For more information about installing the RxDefinitions package, see article PowerStore: Landing Page for RxDefinitions Issues.

Pre-Upgrade Health Checks (PUHC)

LEGEND: In this table, the symbol * indicates checks introduced or enhanced in this most recent Health Check thin package.

Table 3. PowerStore-health_check-4.1.0.0-2720511-retail.tgz.bin PUHC

Test name Description KB Article
off_release_duplicate_or_inconsistent_addresses  Detects duplicate NTP entries PowerStore: Pre-Upgrade Health Check (PUHC) to Identify duplicate NTP Entries
off_release_drive_firmware_check_oe PUHC prevents system instability due to Issue during disk firmware upgrade PowerStore: PUHC to Prevent System Instability Due to Issue During Disk Firmware Upgrade
off_release_volume_metro_reservation_mode_check Detects if one or more Metro volumes are stuck in a synchronization (sync DB) state PowerStore: Pre-upgrade health check (PUHC) to detect 4.0.X metro system with SYM metro volumes stuck in sync DB status
off_release_cpdb_locale_check Detects if the locale or encoding settings in the PowerStore management or local database is correct PowerStore: Database encoding or locale settings of CP database server(s) (localdb/managementdb) are not correctly set
off_release_dpe_drive_check Check if a PowerStore500T with Indus has enough DPE drives PowerStore: A Pre-Upgrade Health Check assesses if a PowerStore500T with an NVMe expansion enclosure (ENS24) has sufficient number of DPE of drives
off_release_check_iscsi_rep_block_size_failed Detects if there are volumes of 4096 bytes size being replicated over iSCSI protocol PowerStore: Pre-Upgrade Health Check (PUHC) detects volumes of 4096 VOLUME SECTOR SIZE being replicated over iSCSI protocol
off_release_rba_configuration_check Determines if the RBA tier is configured PowerStore: Pre-Upgrade Health Check detects that the RBA tier is enabled
iom_activation_check Prevent NDU for IOM/SLIC without activation PowerStore: Health check detects IOPM V2 modules or Ethernet SLICs not properly activated
PS Redundancy  Detects non-redundant power supplies PowerStore: Pre-Upgrade Health Check (PUHC) detects non-redundant power supply
SAS drives with firmware port locked Detects a locked firmware port PowerStore: Pre-Upgrade Health Check for locked firmware port in Samsung SAS drives
off_release_ssd_in_rg_check Detects if an SSD is not in a DRE group PowerStore: Pre-Upgrade Heath Check Detects that Not All the SSDs are in a RAID Group
scheduled_vm_snapshot Detects if there are any VM scheduled snapshots in progress PowerStore: Pre-Upgrade Health Check (PUHC) checks if all snapshot commands are all in completed state
off_release_scsi3_reservation_check Checks the system for any stale SCSI-3 reservations PowerStore: Pre-Upgrade Health Check to Detect a Stale SCSI-3 Reservation Issue
off_release_ens24_drive_missing_path_check Checks the system for non-redundant NVMe drive paths that are either failed or missing PowerStore: Pre-Upgrade Health Check (PUHC) to detect non-redundant NVMe drive paths
pd_manifest_version_check PUHC to ensure Compatibility and Version Control for Rx-Definitions Package in PowerStore PowerStore: Pre upgrade health check (PUHC) to ensure Compatibility and Version Control for Rx-Definitions Package in PowerStore
off_release_incomplete_commands_check PUHC detects incomplete Control Path (CP) commands that are not in the approved list of commands allowed during NDU PowerStore: PUHC to detect incomplete CP commands - off_release_incomplete_commands_check
unsupported_drive_check PUHC detects a system with drives not covered by DriveDB.json v0.6.6.0 PowerStore: Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0
nvram_full_fips_check PUHC detects NVRAM disk's full FIPS is not set correctly PowerStore: System Health Check and/or Pre-Upgrade Health Check 3.x/4.x | Replacement of NVMe NVRAM disks may incorrectly raise FIPS alerts
off_release_removed_third_party_certificate_check Detects a missing third-party certificate chain PowerStore: Pre upgrade health check (PUHC) to detect the reset_certificates REST endpoint issue
off_release_asymmetric_netdevice_check * Detect asymmetrical net device configuration PowerStore: Pre-Upgrade Health Check (PUHC) to Identify Asymmetric NetDevice Configuration
user_db_fewer_records * Detects if necessary user.db entries are lost or different between the nodes of the affected appliance PowerStore: Pre upgrade health check (PUHC) to detect if necessary user.db entries are lost, or different between nodes

System Checks

LEGEND: In this table, the symbol * indicates checks introduced/enhanced in this most recent Health Check thin package.

Table 4. PowerStore-health_check-4.1.0.0-2720511-retail.tgz.bin System Checks

Test name Description KB Article
four_port_iom_state_check Detects if 4PortCard is incorrectly set to fru_is_not_in_use PowerStore: System Health Check detects 4PortCard Incorrectly Set to fru_is_not_in_use
indus_encryption_offset_check Detects drive invalid encryption band location for NVMe expansion enclosures PowerStore: System Check detects drive invalid encryption band location for ENS24 enclosure
unfinished_ndu_check Detects the existence of an unfinished upgrade PowerStore: System Health Check has detected remnants of failed NDU commits
indus_drive_paths_check Detects unstable paths to ENS24 NVMe expansion enclosure PowerStore: System Health Check detects unstable paths to the ENS24 NVMe expansion enclosure.
cpu_ierr_check Checks for CPU internal error PowerStore: System Health Checks detects an issue in the CPU IERR Check
active_system_alert_check Detects active Major and Critical alerts PowerStore: Active alerts detected by health checks
cyc_node_space_check Detects node's /cyc_node directory has insufficient space PowerStore: System Health Checks Detects Lack of Space in cyc_node
time_skew_check Detects unsupported large time skew PowerStore: Health Checks detects high time skew on Nodes and BMC
component_sn_check Detects inconsistent serial number for BBU or PSU PowerStore: System Health Checks detects component Serial Numbers are not consistent: Component SN Check
component_stale_fw_check Detects if the firmware is up to date and if it is compatible with the Dell X.509 signature PowerStore: System Health Checks detects if a firmware upgrade is required
symmd_on_disk_check Detects an out-of-date System Manager Metadata on Disk (SYMMD) data on disks PowerStore: System Health Checks detects an out-of-date System Manager Metadata on Disk (SYMMD) data on disks
invalid_vg_uuid_check Detects if a volume group with no member in Control Path (CP) exists PowerStore: Health Checks detect if a volume group with no members exists
stale_scsi3_reservation_check Detects for any stale SCSI-3 reservations PowerStore: System Health Checks detects a stale SCSI3 reservation issue
kernel_slab_check Detect if any node has slab allocation over the skbuff_fclone_cache limit PowerStore: Health Checks Detect if any Node has Slab Allocation Over the skbuff_fclone_cache Limit
dp_mem_allocation_override_check Detects wrong Data Path (DP) memory settings PowerStore: System Health Checks detects wrong Data Path memory settings
nvme_tcp_dmc_protection_check Detects if an appliance running 4.1.0.0 may be need follow-up to prevent the potential for a data integrity issue PowerStore Health Check to Prevent Data Integrity Scenario on PowerStoreOS 4.1.0.0 clusters with NVMe-TCP LUNs
unsupported_drive_check Detects a system with drives not covered by DriveDB.json v0.6.6.0 PowerStore Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0
nvram_full_fips_check Detects NVRAM disk's full FIPS is not set correctly PowerStore: System Health Check and/or Pre-Upgrade Health Check 3.x/4.x | Replacement of NVMe NVRAM disks may incorrectly raise FIPS alerts

Health Check package for 3.x.

The table below lists the health checks that are in the PowerStore-health_check-3.6.1.5-2691230-retail.tgz.bin Health Check thin package. The package is compatible with PowerStoreOS versions 3.0.x, 3.2.x 3.5.x and 3.6 (including 3.6.1). It is not compatible with 2.x or 4.x.

The Health Check Package contains both validations used by both System Checks and Pre-Upgrade Health Check (PUHC).

Pre-Upgrade Health Checks (PUHC)

LEGEND: In this table, the symbol * indicates checks introduced/enhanced in this most recent Health Check thin package.

Table 5. PowerStore-health_check-3.6.1.5-2691230-retail.tgz.bin PUHC

Test name Description KB Article
duplicate_or_inconsistent_ntp_addresses * Detects duplicate NTP entries PowerStore: Pre-Upgrade Health Check (PUHC) to Identify duplicate NTP Entries
dimm_sn_check * Detects inconsistencies in DIMM serial numbers PowerStore: System Health Checks detects inconsistent DIMM Serial Numbers
off_release_duplicate_or_inconsistent_addresses Detects duplicate NTP entries PowerStore: Pre-Upgrade Health Check (PUHC) to Identify duplicate NTP Entries
off_release_missing_pg_hba_conf_template_check Detects if the pg_hba config template file is missing PowerStore: Pre-Upgrade Health Check (PUHC) detects missing database pg_hba config template file
off_release_nvme_discovered_initiators_check Detects if unassigned NVME_FC initiators are zoned-in and connected to the PowerStore appliance PowerStore: Pre-Upgrade Health to Identify Initiators with no Corresponding Host
off_release_cp_db_location_check In a multi-appliance cluster, detects if some internal PowerStore components are hosted by the same appliance PowerStore: Pre-Upgrade Health Check (PUHC) to Confirm that Primary ControlPath (CP) and Primary Database (DB) are Hosted by the Same Appliance
off_release_cpdb_locale_check Detects if the locale or encoding settings in the PowerStore management or local database is correct PowerStore: Database encoding or locale settings of CP database server(s) (localdb/managementdb) are not correctly set
off_release_check_ndu_pause_rule Detects is "NDU Pause" feature is enabled on the source OS and validates that the destination OS also supports it if applicable PowerStore: Block Non-Disruptive Upgrade (NDU) to Unsupported Build
off_release_locked_drive_check Detects if a drive is in a locked state PowerStore: Per-Upgrade Health Check to Detect if a Drive is Locked
off_release_nvram_full_fips_mode Detects if the full FIPS configuration of NVRAM disks is set correctly PowerStore: System Health Check and/or Pre-Upgrade Health Check 3.x/4.x | Replacement of NVMe NVRAM disks may incorrectly raise FIPS alerts
off_release_unsupported_drive_check Detects if all drives installed are found in the system driveDB.json file PowerStore Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0
off_release_check_db_rep_mode_failed Detects and stops clusters of 3 or 4 appliances from upgrading to PowerStoreOS 4.1 PowerStore: After an upgrade to PowerStoreOS 4.1 on clusters with three or more appliances, management database replication may remain in async mode
off_release_drive_wear_check Determines if there are drives whose wear level is too high PowerStore: The Pre-Upgrade Health Check (PUHC) determines if there are drives whose wear level is too high.
off_release_dpe_drive_check Check if a PowerStore500T with Indus has enough DPE drives PowerStore: A Pre-Upgrade Health Check assesses if a PowerStore500T with an NVMe expansion enclosure (ENS24) has enough of DPE of drives.
off_release_drivedb_check Detects incorrect drive database file PowerStore: Pre-Upgrade Health Check (PUHC) detects incorrect drive Database signature.
off_release_check_iscsi_rep_block_size_failed Detects if there are volumes of 4096 bytes size being replicated over iSCSI protocol PowerStore: Pre-Upgrade Health Check (PUHC) detects volumes of 4096 VOLUME SECTOR SIZE being replicated over iSCSI protocol
efi_boot_check
off_release_efi_boot_check
Check that the correct boot entry option is used PowerStore: Pre-Upgrade Heath Check detects if reboot was using an incorrect boot entry option
off_release_rba_configuration_check Determines if the RBA tier is configured PowerStore: Pre-Upgrade Health Check to detect if RBA tier is enabled.
iom_activation_check Prevent NDU for IOM/SLIC without activation PowerStore: Health check has detected that a NVMe Expansion Enclosure (ENS24) was added but not recognized.
silent_drive_failure_check Detects if an underlying firmware upgrade process is running PowerStore: Health check detects the missing SSD issue
off_release_check_proc_install_disk_firmware Detects if an underlying firmware upgrade process is running PowerStore: Pre-Upgrade Heath Check detects an underlying firmware upgrade process is running
off_release_ssd_in_rg_check Detects if an SSD is not in a DRE group PowerStore: Pre-Upgrade Heath Check Detects that Not All the SSDs are in a RAID Group
SAS drives with firmware port locked Detects a locked firmware port PowerStore: Pre-Upgrade Health Check for locked firmware port in Samsung SAS drives
PS Redundancy Detects non-redundant power supplies PowerStore: Pre-Upgrade Health Check (PUHC) detects non-redundant power supply
replication_session_state Detects replication session is in progress PowerStore: Pre-upgrade Health Check (PUHC) detects replication is in a state that prevents NDU.
scheduled_vm_snapshot Detects if there are any VM scheduled snapshots in progress PowerStore: Pre-Upgrade Health Check (PUHC) checks if all snapshot commands are all in completed state.
off_release_check_chap_authentication off_release_check_chap_authentication PowerStore: Pre-Upgrade Health Check (PUHC) detects if the CHAP transit connection is properly configured.
The maintenance window is configured. Detects if a maintenance window has been configured. Only relevant for OS versions where the system does not automatically enable the maintenance window before NDU PowerStore: Pre-Upgrade Health Check (PUHC) detects that the maintenance window has not been configured
Detect a secondary IP issue. Detects secondary IP issue on NVMe expansion enclosure PowerStore: Pre-upgrade Health Check (PUHC) detects an issue with the secondary IP setting on an ENS24 NVMe expansion enclosure.
SDNAS snapshot limit Detects if SDNAS snapshots exceeded their limit PowerStore: System Health Check detects that the SDNAS snapshot limit has been exceeded
Duplicate FW entry check Detects duplicate component firmware entries in a node's resume (registry) PowerStore: System Health Checks detects duplicate firmware entries
Initiator connectivity check Detects if any nonredundant initiators exist PowerStore: System Health Checks Detected Nonredundant Initiators
Reboot flag set Detects if the reboot flag is set PowerStore: System Health Checks detects the reboot flag is set
Recovery partition image check Detects incorrect filename in recovery partition PowerStore: Health check detects an issue with the filename, recovery partition, or PowerStoreOS package version
off_release_sdnas_remote_network_alert_check Detects NAS replication interface mismatch PowerStore: Pre-Upgrade Health Check (PUHC) detects Interface mismatch for NAS replication sessions
off_release_stale_scsi3_reg_check Checks the system for any stale SCSI-3 reservations PowerStore: Pre-Upgrade Health Check to Detect a Stale SCSI-3 Reservation Issue
empty_vg_no_memebers Detects if a volume group with no member in Control Path (CP) exists PowerStore: Health Checks detect if a volume group with no members exists
off_release_ens24_drive_missing_path_check Checks the system for non-redundant NVMe drive paths that are either failed or missing PowerStore: Pre-Upgrade Health Check (PUHC) to detect non-redundant NVMe drive paths
off_release_scsi3_reservation_check Checks the system for any existing SCSI-3 reservations PowerStore: Pre-Upgrade Heath Check Detects existing SCSI3 reservations
off_release_sdnas_last_event_id_check Detects if the SdnasLastProcessedEventId number is large enough to cause an Out of Memory issue PowerStore: Pre upgrade health check (PUHC) to detect if the SdnasLastProcessedEventId number is large enough to cause an Out of Memory issue.
off_release_new_firmware_zip_existence_check Detects a lost pre-staged FW .zip file issue to prevent NDU failure PowerStore: Pre upgrade health check (PUHC) to detect if the "new FW zip is wiped out from the stage of FW partition"
off_release_sdnas_memory_config Detects if there is a mismatch between the platform's limit for the NAS container versus what the NAS attempts to internally allocate PowerStore: Pre upgrade health check (PUHC) to detect an SDNAS memory configuration issue
off_release_nvme_reservation_check Detects if NVMe Reservations are present on the cluster PowerStore: Pre upgrade health check (PUHC) to detect if NVMe reservations are present on the cluster
off_release_dp_mem_override_file_exists Detects the presence of an existing Data Path (DP) memory override file PowerStore: Pre upgrade health check (PUHC) to detect OOM override for Data Path Memory
off_release_removed_third_party_certificate_check Detects a missing third-party certificate chain PowerStore: Pre upgrade health check (PUHC) to detect the reset_certificates REST endpoint issue
user_db_fewer_records Detects if necessary user.db entries are lost or different between the nodes of the affected appliance PowerStore: Pre upgrade health check (PUHC) to detect if necessary user.db entries are lost, or different between nodes
off_release_vol_in_destroying_state_check Detects if volumes in "Destroying" state PowerStore: Pre-upgrade health check (PUHC) to detect volumes in "Destroying" state
off_release_incomplete_commands_check Detects incomplete Control Path (CP) commands that are not in the approved list of commands allowed during NDU PowerStore: PUHC to detect incomplete CP commands - off_release_incomplete_commands_check
off_release_inter_cluster_tcp_conn_check Detects partial inter-cluster TCP connections PowerStore: Pre upgrade health check (PUHC) to detect partial inter-cluster TCP connections
off_release_stale_gsips_in_remote_rtps_check Detects any non-existing global storage discovery IP (GSIP) left over in the remote relative target ports (RTPs) PowerStore: Pre-Upgrade Health Check to Detect a stale GSIP in remote RTPs

System Checks

LEGEND: In this table, the symbol * indicates checks introduced/enhanced in this most recent Health Check thin package.

Table 6. PowerStore-health_check-3.6.1.5-2691230-retail.tgz.bin System Checks

Test name Description KB Article
off_release_nvram_full_fips_mode Detects if the full FIPS configuration of NVRAM disks is set correctly PowerStore: System Health Check and/or Pre-Upgrade Health Check 3.x/4.x | Replacement of NVMe NVRAM disks may incorrectly raise FIPS alerts
off_release_unsupported_drive_check Detects if all drives installed are found in the system driveDB.json file PowerStore Health Checks to Identify a System with Drives not covered by DriveDB.json v0.6.6.0
ppds_dsb_check Detects outdated DSB information PowerStore: System Checks detects that the platform data service information is out of date.
indus_encryption_offset_check Detects drive invalid encryption band location for NVMe expansion enclosures PowerStore: System Check detects NVMe expansion enclosure (ENS24) drive invalid encryption band location.
dp_dedupe_destage_leak_check Detect unwanted destages to cause excessive drive wear PowerStore: System Check detects unnecessary de-stages
kr_link_boot_option_check Detect if the KR link PXE boot option is not enabled on both nodes of 500T appliances PowerStore: System Check detects if the KR link PXE boot option is not enabled on both nodes for PowerStore 500T appliances.
iom_activation_check Prevent NDU for IOM/SLIC without activation PowerStore: Health check has detected that a NVMe Expansion Enclosure (ENS24) was added but not recognized.
dp_resiliency_mode_check Detect ungraceful exit of resiliency mode (vDisk issue) PowerStore: System Checks detects that the appliance unnecessarily remains in resiliency mode.
sdnas_capacity_alert_check Detect if FS capacity alert disabled after upgrade PowerStore: Filesystem usage capacity alerts disabled after upgrade.
unfinished_ndu_check Detects the existence of an unfinished upgrade PowerStore: System health Check has detected remnants of failed NDU commits.
silent_drive_failure_check Detects issue of KB 000216381 PowerStore: SSD Failed Without an Alert Being Displayed PowerStore: Heath check detects the missing SSD issue.
target_port_group_id_check Detects a target port group issue affecting mapping of an NVMeoF volume PowerStore: System health check detects a target port group issue that may affect mapping of an NVMeoF volume.
indus_drive_paths_check Detects unstable paths to ENS24 NVMe expansion enclosure PowerStore: System Health Check detects unstable paths to the ENS24 NVMe expansion enclosure.
dimm_sn_check Detects inconsistencies in DIMM serial numbers PowerStore: System Health Checks detects inconsistent DIMM Serial Numbers.
recovery_partition_image_check Detects an incorrect filename in the recovery partition PowerStore: System Health Checks for incorrect filename in recovery partition.
duplicate_fw_entry_check Detects duplicate component firmware entries in a node's resume (registry) PowerStore: System Health Checks detects duplicate firmware entries.
cpu_ierr_check Checks for CPU internal error PowerStore: System Health Checks detects an issue in the CPU IERR Check.
InitiatorConnectivityCheck Detects nonredundant initiators PowerStore: System Health Checks Detected Nonredundant Initiators.
icd_network_check Detects missing connectivity to ToR PowerStore: System Health Checks detected an ICD Network Connectivity issue.
dimm_correctable_error_check Detects DIMM Correctable Errors (CE) count (5k threshold) PowerStore: System Health Checks detects excessive DIMM Correctable Errors (CE) count.
active_system_alert_check Detects active Major and Critical alerts PowerStore: Active alerts were detected by health checks.
cyc_node_space_check Detects node's /cyc_node directory has insufficient space PowerStore: System Health Checks detects lack of space in /cyc_node.
time_skew_check Detects unsupported large time skew PowerStore: System Health Checks detects high time skew on Nodes and BMC.
db_tmpfiles_check Detects database temporary files larger than expected PowerStore: System Health Checks detects large database temporary files.
bbu_sensor_check Detects failure in various BBU health checks PowerStore: System Health Checks detects invalid battery status.
component_sn_check Detects inconsistent serial number for BBU or PSU PowerStore: System Health Checks detects that component Serial Numbers are not consistent: fru_items_sn_check
fsck_leftover_check Detects if there exists the fsck generated file cyc-sys-mode-override.txt PowerStore: System Health Checks detects recovery file.
component_stale_fw_check Detects if the firmware is up to date and if it is compatible with the Dell X.509 signature PowerStore: System Health Checks detects if a firmware upgrade is required.
transit_connection_check Detects if transit connection objects exist in the Data Path PowerStore: System Check detects orphan transit connection objects
symmd_on_disk_check Detect if the latest System Manager Metadata on Disk (SYMMD) data is saved on disk PowerStore: System Health Checks detects an out-of-date System Manager Metadata on Disk (SYMMD) data on disks
kernel_slab_check Detect if any node has slab allocation over the skbuff_fclone_cache limit PowerStore: System Health Checks detects if any node has slab allocation over the skbuff_fclone_cache limit

Health Check package for 2.1.x.

The table below lists the health checks that are in the PowerStore-health_check-2.1.1.2-2069723-retail.tgz.bin Health Check thin package. The package is compatible with PowerStoreOS versions 2.1.x. It is not compatible with versions 3.x or 4.x.

Table 7. PowerStore-health_check-2.1.1.2-2069723-retail.tgz.bin Health Check

Test name Description KB for failure
mtc_drive_counter_check Detects an MTC NVRAM drive issue PowerStore: System Health Check detects an MTC NVRAM drive issue.
drive_flags_check Detects offline and failed drives including those that do not raise an alert PowerStore: System Health Check detects an offline or failed SSD.
bbu_sensor_check Detects failure in various BBU health checks PowerStore: System Health Checks detects invalid battery status.
kms_lockbox_file_check Detects an issue with the dare lockbox PowerStore: Health check detects an issue with the lockbox.
os_package_name_check Detects incorrect filename in recovery partition PowerStore: Health check detects an issue with the filename, recovery partition, or PowerStoreOS package version.
duplicate_fw_entry_check Detects duplicate component firmware entries in a node's resume (registry). PowerStore: System Health Checks detects duplicate firmware entries.
fsck_leftover_check Detected unexpected recovery files PowerStore: System Health Checks detects recovery file.
recovery_partition_image_check Detects incorrect filename in recovery partition PowerStore: System Health Checks for incorrect filename in recovery partition.
symmetric_icm_connection Detects missing ICM connection PowerStore: Heath Check package check for asymmetric ICM connections fails
cpu_ierr_check Checks for CPU internal error PowerStore: System Health Checks detects an issue in the CPU IERR Check.
InitiatorConnectivityCheck Detects nonredundant initiators PowerStore: System Health Checks Detected Nonredundant Initiators.
icd_network_check Detects missing connectivity to ToR PowerStore: System Health Checks detected an ICD Network Connectivity issue.
symmd_fw_upgrade_flag_check Detects a PSU in an invalid state PowerStore: System Health Checks detects an incorrect PSU State.
dimm_correctable_error_check Detects DIMM CE count (5k threshold) PowerStore: System Health Checks detects excessive DIMM Correctable Errors (CE) count.
active_system_alert_check Detects active Major and Critical alerts PowerStore: Active alerts were detected by health checks.
cyc_node_space_check Detects node's /cyc_node directory has insufficient space PowerStore: System Health Checks detects lack of space in /cyc_node.
time_skew_check Detects unsupported large time skew PowerStore: System Health Checks detects high time skew on Nodes and BMC.
db_tmpfiles_check Detects database temporary files larger than expected PowerStore: System Health Checks detects large database temporary files.
bbu_ipmi_i2c_check Detects failure in various BBU health checks PowerStore: System Health Checks detects invalid battery status.
ru_items_sn_check Detects inconsistent serial number for BBU or PSU PowerStore: System Health Checks detects that component Serial Numbers are not consistent: fru_items_sn_check

 

Affected Products

PowerStore
Article Properties
Article Number: 000214752
Article Type: How To
Last Modified: 22 May 2026
Version:  46
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.