Dell EMC VxRail:节点删除期间预先检查失败
Summary: 当节点进入 MM 模式时,节点的存储容量已从 vSAN 数据存储区中删除。 但是,在节点删除的预检查期间,VxRail Manager 再次减少节点存储,从而导致问题。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
在节点删除期间,容量预检查失败,在以下日志中发现类似错误。
web.log
INFO [Thread-908] com.emc.mystic.manager.web.service.nodes.action.PrecheckAction PrecheckAction.perform:43 - Failed to do PrecheckAction...
at com.emc.mystic.manager.web.webutil.RestException.NodeRemovalPrecheckFailedException(RestException.java:423) ~[classes/:?]
at com.emc.mystic.manager.web.service.nodes.action.PrecheckAction.perform(PrecheckAction.java:44) ~[classes/:?]
at com.emc.mystic.manager.web.service.nodes.action.PrecheckAction.perform(PrecheckAction.java:44) ~[classes/:?]
“operation_status”表
d3755ec2-e6c2-4468-9f8f-fb91b0688185 HOST_REMOVAL FAILED {"objectClass":"com.emc.mystic.manager.commons.db.bean.OperationStatusError","objectString":"{\\"subErrorCode\\":1006,\\"detail\\":{\\"localizableMessage\\":{\\"bundle\\":\\"RestError\\",\\"key\\":\\"1006\\",\\"__LocalizableMessage__\\":true},\\"__LocalizableMessageWithParams__\\":true}}"} 13 1552629558789 1552629657987 \N PrecheckAction \N [{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"MaintenanceModeValidationAction\\",\\"status\\":true}"},{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"MinimalNodeChecker\\",\\"status\\":true}"},{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"ResourceCapacityChecker\\",\\"status\\":false,\\"message\\":{\\"bundle\\":\\"NodeOperation\\",\\"key\\":\\"node.removal.capacity.check\\",\\"__LocalizableMessage__\\":true}}"},{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"ResourceCPUChecker\\",\\"status\\":true}"},{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"ResourceMemoryChecker\\",\\"status\\":true}"},{"objectClass":"com.emc.mystic.manager.web.service.nodes.action.ActionStatusBean","objectString":"{\\"name\\":\\"VsanHealthyChecker\\",\\"status\\":true}"}]
Cause
当节点进入 MM 模式时,节点的存储容量已从 vSAN 数据存储区中删除。
但是,在节点删除的预检查期间,VxRail Manager 再次减少节点存储,从而导致问题。
但是,在节点删除的预检查期间,VxRail Manager 再次减少节点存储,从而导致问题。
Resolution
请按照以下步骤再次执行节点删除。
- 选择节点以进入 MM 模式
- 右键单击节点,然后选择“断开连接”
- 清除严重警报
- 右键单击节点> ,选择 “VxRail”,然后选择> “移动 VxRail 主机”
- 使用所需的凭据执行节点删除
- 如果必须删除多个节点,请重复步骤 1 - 步骤 5。