Cisco: F16_PLDA_RXBUF_MERR exception error

Summary: F16_PLDA_RXBUF_MERR error on a single port ASIC results in a complete module reload.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

16G FC module in an MDS 9700 reloaded due to an F16_PLDA_RXBUF_MERR error on one F16 ASIC. This is an uncorrectable ECC error. The specific port range identified should be put into Hardware Failure state instead of the entire module being reloaded.
Applies to F16_PLDA_RXBUF_MERR errors on DS-X9448-768K9 and DS-X9334-K9 modules only

2020 Jan 1 00:42:40.617 %MODULE-2-MOD_DIAG_FAIL: Module 3 (Serial number: XXXXXXXXXXX) reported failure fc3/1-48due to unrecoverable catastrophic error in device DEV_F16_CMN (device error 0xxxxxxxx)

Exception Log Record : Wed Jan 1 00:42:39 2020 (817874 us) Device Id : 204 Device Name : F16 Generic Driver Device Error Code : ccc03600(H) Device Error Type : ERR_TYPE_INTR Device Error Name : NULL Device Instance : 3 Sys Error : unrecoverable catastrophic error Errtype : CATASTROPHIC PhyPortLayer : Fibre Channel Port(s) Affected : 1-48 Error Description : F16_PLDA_RXBUF_MERR DSAP : 0 UUID : 1129 Time : Wed Jan 1 00:42:39 2020 (817874 usecs 5E0B7A7F(H) jiffies)

 

Cause

Cisco bug CSCvs57660This hyperlink is taking you to a website outside of Dell Technologies.

 

Resolution

Upgrade NX-OS code to 6.2.31 or 8.4.2 and higher code versions.

 

Affected Products

Connectrix MDS-9710

Products

Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718