NOTE: Port-channels can be static or dynamic.
- Static Port-channels are statically configured. To configure static, use mode 'ON'.
- Dynamic Port-channels are dynamically configured using Link Aggregation Control Protocol (LACP). Dynamic port channels can be active or passive.
- Mode = Active sets the interface in the Active Negotiation state with LACP. A port in Active mode can setup a port channel with another port in Active or Passive
- Mode = Passive sets the interface in the Inactive Negotiating state, but LACP runs on the link. A passive mode link responds to active negotiation requests, but will not setup a link with another passive mode port.
Port-channel topology
Figure 1: Example Topology
Prerequisites:
- Switches #1 and #2 exist with links between them on ports 1/1/33 and 1/1/34 (Figure 1).
Instructions
Instructions for setting up a port channel between two switches
- Open the CLI using the console or management IP for your S-series switches #1 and #2.
- Log in to the privileged exec mode as default admin credentials (OS10 user=admin, password=admin).
- To modify the switch configuration on switch #1, run the
configure terminalcommand to enter global configuration mode, then press enter.
OS10# configure terminal OS10(config)#
- To create port channel 1, enter the command
interface port channel 1:
OS10(config)# interface port-channel 1 OS10(conf-if-po-1)#
- To exit the interface mode, use
exit:
OS10(conf-if-po-1)# exit OS10(config)#
- Configure which interfaces are in the port channel with
interface range Ethernet 1/1/33-1/1/34:
OS10(config)# interface range ethernet 1/1/33-1/1/34 OS10(conf-range-eth1/1/33-1/1/1/34)#
- Configure the Ethernet ports to be added to port channel 1 with active LACP using
channel-group 1 mode active:
OS10(conf-range-eth1/1/33-1/1/1/34)# channel-group 1 mode active OS10(conf-range-eth1/1/33-1/1/1/34)#
- Exit the interface and configuration back to exec mode with the command
end:
OS10(conf-range-eth1/1/33-1/1/1/34)# end OS10#
- On SWITCH #2 repeat the steps from SWITCH #1.
- Verify the configuration changes made on the interface with the command
show interface port channel summary:
OS10# show interface port-channel summary LAG Mode Status Uptime Ports 1 L2 up 00:00:30 Eth 1/1/33 (Up) Eth 1/1/34 (Up) OS10#
- Show the interface port channel detailed information with
show interface port channel 1command:
OS10# show interface port-channel 1 Port-channel 1 is up, line protocol is up Address is 0c:d3:b9:6e:00:51, Current address is 0c:d3:b9:6e:00:51 Interface index is 125 Internet address is not set Mode of IPv4 Address Assignment: not set Interface IPv6 oper status: Disabled MTU 1532 bytes, IP MTU 1500 bytes LineSpeed 50G Minimum number of links to bring Port-channel up is 1 Maximum active members that are allowed in the portchannel is 32 Members in this channel: Eth 1/1/33-1/1/34 …
- Verify the configuration changes made on the interface with the command
show running-configuration interface Ethernet 1/1/33:
OS10# show running-configuration interface ethernet 1/1/33 ! interface ethernet1/1/33 no shutdown channel-group 1 mode active no switchport flowcontrol receive off OS10#
- Verify the port channel configuration with the command
show running-configuration interface port channel 1:
OS10# show running-configuration interface port-channel 1 ! interface port-channel1 no shutdown switchport access vlan 1 OS10# Switch #1 show interface port-channel summary Switch #2 show interface port-channel summary
- To save the configuration changes, use the command
write memory.
OS10# write memory OS10#
For further assistance, see theDell Technologies SmartFabric OS10 User Guide Release Documentation or reach out to Dell Technologies Technical Support.
Affected Products
Networking, PowerSwitch S3048-ON, PowerSwitch S4048-ON, Dell EMC PowerSwitch N3000E-ON Series, PowerSwitch S4048T-ON, PowerSwitch S4112F-ON/S4112T-ON, PowerSwitch S4128F-ON/S4128T-ON, PowerSwitch S4148F-ON/S4148T-ON/S4148FE-ON, PowerSwitch S4148U-ON
, PowerSwitch S4248FB-ON /S4248FBL-ON
...
Products
PowerSwitch S5048F-ON, PowerSwitch S5148F-ON, PowerSwitch S5212F-ON, PowerSwitch S5224F-ON, PowerSwitch S5232F-ON, PowerSwitch S5248F-ON, PowerSwitch S5296F-ON, PowerSwitch S5448F-ON, SmartFabric OS10 SoftwareArticle Properties
Article Number: 000204226
Article Type: How To
Last Modified: 30 Nov 2023
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.