PowerEdge:安裝 MX760c SLED 後,出現 MX7000 風扇警告
Summary: Open Manage Enterprise 中的風扇警告訊息:在銷售點後 (APOS) 將 MX760c SLED 安裝至 MX7000 機箱後的模組化 (OME-M)。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
這是風扇警告訊息的範例,但在機箱隨附的所有風扇上均可看到。
===================================================== Front fan 1 requires attention for optimal performance. Desc: A device in the chassis requires a fan type that does not match the configuration of the fan identified in the message. Some devices may experience varied performance and possible thermal errors depending on the configuration, workload, and environment. Action: Replace the fan with a Gen2 fan during the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 User's Guide available on the support site. =====================================================
Cause
對於需要最佳化機箱之 MX7000 的 MX7600 運算模組,在購買和安裝運算模組之前,並未檢查其散熱和電源最佳化需求。
Resolution
在銷售點後安裝 MX760C SLED 時,必須遵循下列 MX7000 機箱上的升級:
- MX7000 黃金級 (硬體版本 2,Gen 2) 風扇 (客戶套件 PN:H2YC5/SKU:貨號 750-ADWN;隨附於 MX760c 的 MX 解決方案訂單中)
- Open Manage Enterprise - 模組化 (OME-M) 韌體版本 2.00.00
- iDRAC 版本 05.10.25 或 06.10.05
- 企業基礎結構規劃工具 (EIPT)
注意:選取或升級系統組態時,請使用 Enterprise Infrastructure Planning Tool 確認系統耗電量,以確保最佳的電源使用率。
注意:若要產生散熱最佳化 SLED 至插槽配置,請在 EIPT 工具中輸入 MX 組態,然後按一下最佳化。
如需完整資訊,請參閱 Dell 支援產品頁面的《 MX760c 安裝與維修手冊 》。
Affected Products
PowerEdge MX7000, PowerEdge MX760cArticle Properties
Article Number: 000215534
Article Type: Solution
Last Modified: 07 May 2026
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.