PowerProtect Data Manager: Falha ao criar a unidade de armazenamento com o código de erro CFG0001
Summary: Falha ao criar unidade de armazenamento com o código de erro CFG0001
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Ao criar uma nova política, ela falha ao criar a unidade de armazenamento.
Na interface do usuário:
Na interface do usuário:
CFG0001: xxx: Unable to configure the protection policy because of the following error: Failed to connect to PowerProtect DD System. errorNum: 5007 errorMessage: operation is not implementedNo registro de trabalhos:
ddboost.log: 2023-08-11T23:15:17.931Z ERROR [] [pool-26-thread-1] [00000000-0000-4000-b000-000000000000][][][TRACE_ID:81a3388041e49793;JOB_ID:9ea4884359c07119][plc.id:2eab4e3d,asset.id:,pcs.id:] ddboost.log(52) - severity:1 msg:[D688:7FF690077BA0] ddp_connect_with_config() failed, Hostname: xxx, Err: 5007-nfs ddp getinfo failed (nfs: Operation not supported)Confirmado que não há nenhum problema de rede ou de certificado, já usando sysadmin para adicionar o Data Domain (a detecção está funcionando bem).
Cause
O serviço NFS do Data Domain está desabilitado.
Resolution
Na interface do usuário do Data Domain, clique em "ENABLE" para habilitar o NFSv3.
Affected Products
PowerProtect Data Manager, PowerProtect SoftwareArticle Properties
Article Number: 000216695
Article Type: Solution
Last Modified: 18 May 2026
Version: 6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.