PowerFlex: SDC-fejl: Kunne ikke hente den lokale sokkeladresse for soklen

Summary: Efter en nodegenstart blev SDC-fejl fundet i /var/log/messages med "Failed to fetch socket local address for socket".

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

/var/log/messages Vil rapportere følgende fejl ved nodegenstart:

Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 0000000036f5061f with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000478b06fd with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000ec72fcc2 with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000248b334d with Errno 16

 

Påvirkning 

Der er ingen indvirkning; Den rapporterede fejl er kosmetisk. 

Cause

Problemet opstår som følge af en fejl i koden, der udelader SDC's lokale sokkeladresse i rapporter om portklap til MDM efter en nodegenstart.

Selvom denne fejl er klassificeret som kosmetisk, påvirker den ikke MDM's processer, da den ikke bruger disse adresser. Derfor er der ingen indvirkning på systemets ydeevne eller funktionalitet.

Resolution

Ignorer fejlen i /var/log/messages, indtil klyngen opgraderes til den korrekte version nedenfor.

Påvirket version

PowerFlex SDC 3.6.3

PowerFlex SDC 4.x

Fast i version

PowerFlex SDC 3.6.4

PowerFlex SDC 4.5.3

Affected Products

PowerFlex Software
Article Properties
Article Number: 000224276
Article Type: Solution
Last Modified: 30 Dec 2025