PowerFlex: SDC 오류: 소켓의 소켓 로컬 주소를 검색하지 못했습니다.
Summary: 노드 재부팅 후 /var/log/messages에서 "Failed to retrieve socket local address for socket"과 함께 SDC 오류가 발견되었습니다.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
/var/log/messages 노드 재부팅 시 다음 오류를 보고합니다.
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 0000000036f5061f with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000478b06fd with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000ec72fcc2 with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000248b334d with Errno 16
영향
영향이 없습니다. 보고된 오류는 표면적인 오류입니다.
Cause
이 문제는 노드 재부팅 후 MDM에 대한 포트 플래핑 보고서에서 SDC의 로컬 소켓 주소를 생략하는 코드의 결함으로 인해 발생합니다.
이 오류는 표면적인 오류로 분류되지만 MDM은 이러한 주소를 사용하지 않으므로 MDM의 프로세스에는 영향을 주지 않습니다. 따라서 시스템의 성능이나 기능에 영향을 미치지 않습니다.
Resolution
클러스터가 아래의 고정 버전으로 업그레이드될 때까지 /var/log/messages의 오류를 무시하십시오.
영향을 받는 버전
PowerFlex SDC 3.6.3
PowerFlex SDC 4.x
수정된 버전
PowerFlex SDC 3.6.4
PowerFlex SDC 4.5.3
Affected Products
PowerFlex SoftwareArticle Properties
Article Number: 000224276
Article Type: Solution
Last Modified: 30 Dec 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.