PowerFlex:SDC 错误:无法检索套接字的套接字本地地址
Summary: 节点重新启动后,在 /var/log/messages 中发现 SDC 错误,并显示“无法检索套接字的套接字本地地址”。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
/var/log/messages 将在节点重新启动时报告以下错误:
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 0000000036f5061f with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000478b06fd with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000ec72fcc2 with Errno 16
Mar 6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000248b334d with Errno 16
影响
没有影响;报告的错误是表面错误。
Cause
此问题源于代码中的一个缺陷,该缺陷在节点重新启动后向 MDM 报告的端口摆动中省略了 SDC 的本地套接字地址。
虽然此错误被归类为表面错误,但它不会影响 MDM 的进程,因为它不使用这些地址。因此,这不会影响系统的性能或功能。
Resolution
忽略 /var/log/messages 中的错误,直到群集升级到下面的修复版本。
受影响的版本
PowerFlex SDC 3.6.3
PowerFlex SDC 4.x
已修复问题的版本
PowerFlex SDC 3.6.4
PowerFlex SDC 4.5.3
Affected Products
PowerFlex SoftwareArticle Properties
Article Number: 000224276
Article Type: Solution
Last Modified: 30 Dec 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.