PowerProtect: Cyber Recovery Partially analyzed point-in-time copy
Summary: Cyber Recovery Alert message ID 3008 Summary: Partially analyzed point-in-time copy.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Cyber Recovery 19.16 with CyberSense 8.6
Alert Message ID: 3008
Severity: Warning
Summary: Partially analyzed point-in-time copy.
Description: The application performed a partial analysis on the requested point-in-time copy.
Alert Message ID: 3008
Severity: Warning
Summary: Partially analyzed point-in-time copy.
Description: The application performed a partial analysis on the requested point-in-time copy.
Cause
Virtual Machine backups with an uninitialized disk or unknown partition type, found in ie_run.log in Cybersense.
In /opt/ie/var/log run
For example, using 2024-05-23 as date in our scenario
In /opt/ie/var/log run
"grep -i INDEXING_FAILURE ie_run_log | date"
For example, using 2024-05-23 as date in our scenario
[root@cybersense var]# grep -i INDEXING_FAILURE ie_run.log | grep "2024/05/23"
2024/05/23 08:39:45 error: FI:7fc469ffd640:304:INDEXING_FAILURE: Indexing failed for job 5, bkup time 1716433222, host [xxx.yyyy.local, NetWorker VMDK backup [/opt/ie/var/mnt/dispatch/crawl_FavyDz/VMWE01/86/47/3ec313b2-00000006-e54eb13f-664eb13f-1d1c0c00-12c3df29/BackupDescriptor.], fn [vm-5096-disk-key-2001.vmdk], image: [/opt/ie/var/mnt/dispatch/VMDK_08yPCg/flat], err [uninitialized disk or unknown partition type]
Resolution
Remove the uninitialized disk or unknown partition type from the Virtual Machine.
After new sync-copy-analyze, the warning does not occur.
After new sync-copy-analyze, the warning does not occur.