Connectrix: Cisco MDS: Modulnulstilling Systemfejlkode 0x42b8001e fatal fejl.

Summary: Problemet opstår, hvor modulet nulstilles, og et par porte går i "hw_Failure"-tilstand. Det specifikke portinterval, der er identificeret, skal sættes i hardwarefejltilstand, men i stedet for at hele modulet genindlæses. Fejlen "F16_PLDA_RETRY_MERR" er en multibit ECC-fejl, uoprettelig hardwarefejl. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Det specifikke portinterval går i tilstanden "hw_Failure":

`show interface brief`
-----------------------------------------------------------------------------------------
Interface  Vsan   Admin  Admin   Status       SFP    Oper  Oper   Port     Logical
                  Mode   Trunk                       Mode  Speed  Channel   Type
                         Mode                              (Gbps)
-----------------------------------------------------------------------------------------
fc9/41      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/42      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/43      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/44      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/45      1      FX     off     hwFailure    swl   --     --     --       --       
fc9/46      1      FX     off     hwFailure    swl   --     --     --       --       
fc9/47      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/48      1      E      on      hwFailure    swl   --     --     57       --    

Fejlkoden vises i modulets interne undtagelseslog som nedenfor:

`show module internal exceptionlog module 9`
********* Exception info for module 9 ********
exception information --- exception instance 1 ----
Module Slot Number: 9
Device Id         : 204
Device Name       : F16 Generic Driver
Device Errorcode  : 0xccc05600
Device ID         : 204 (0xcc)
Device Instance   : 05 (0x05)
Dev Type (HW/SW)  : 06 (0x06)
ErrNum (devInfo)  : 00 (0x00)
System Errorcode  : 0x42b8001e fatal error
Error Type        : FATAL error
PhyPortLayer      : Fibre Channel
Port(s) Affected  : fc9/41-48
Error Description : F16_PLDA_RETRY_MERR
DSAP              : 0 (0x0)
Time              : Mon Jan  6 22:22:32 2025
                    (Ticks: 677CAC08 jiffies)

En modulnulstilling ses i showet logføring af nvram:

`show logging nvram`
2025 Jan  6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600)
2025 Jan  6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE
`show logging log`
2025 Jan  6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600)
2025 Jan  6 22:22:32 WTXA19710H15 %PORT-CHANNEL-5-PORT_DOWN: port-channel57: fc9/48 is down
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/48 is down (Hardware Failure) port-channel57 ISL to WTXA19710C02 fc7/22 
2025 Jan  6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/47 is down (Hardware Failure)  ltx15brwccas01_h0 
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/46 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/45 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/44 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/43 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/42 is down (Hardware Failure)  ltx14brwccas02_h0 
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/41 is down (Hardware Failure)  ltx14brwccas01_h0 

 

Cause

Den DEV_F16_CMN fejl på en switch i Cisco MDS 9000-serien indikerer typisk et hardwareproblem relateret til F16 ASIC. Denne fejl resulterer ofte i, at modulet genstarter på grund af en uoprettelig ECC-fejl (Error-Correcting Code) med flere bit.

Resolution

Den eneste måde at gendanne en grænseflade fra hw_Failure er at genindlæse modulet forstyrrende.

#reload module x

Hvis grænsefladerne er i en midlertidig hardwarefejl, kan status gendannes ved modulgenindlæsning. Hvis grænsefladerne har en permanent hardwarefejl, skal du fortsætte med moduludskiftning.

 

ADVARSEL: Aktiviteten er forstyrrende og bør udføres under vedligeholdelsesvinduet.

 

Additional Information

SR #203555104 

Affected Products

Connectrix MDS-Series Hardware
Article Properties
Article Number: 000271449
Article Type: Solution
Last Modified: 03 Feb 2025
Version:  1