Connectrix: Cisco MDS: Tilbakestilling av modul Systemfeilkode 0x42b8001e uopprettelig feil.
Summary: Problemet oppstår der modulen tilbakestilles og noen porter går i "hw_Failure"-tilstand. Det spesifikke portområdet som identifiseres, bør settes i maskinvarefeiltilstand, men i stedet for at hele modulen lastes inn på nytt. Feilen "F16_PLDA_RETRY_MERR" er en multibit ECC-feil, uopprettelig maskinvarefeil. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Det spesifikke portområdet går inn i "hw_Failure"-tilstand:
`show interface brief` ----------------------------------------------------------------------------------------- Interface Vsan Admin Admin Status SFP Oper Oper Port Logical Mode Trunk Mode Speed Channel Type Mode (Gbps) ----------------------------------------------------------------------------------------- fc9/41 1400 FX off hwFailure swl -- -- -- -- fc9/42 1400 FX off hwFailure swl -- -- -- -- fc9/43 1400 FX off hwFailure swl -- -- -- -- fc9/44 1400 FX off hwFailure swl -- -- -- -- fc9/45 1 FX off hwFailure swl -- -- -- -- fc9/46 1 FX off hwFailure swl -- -- -- -- fc9/47 1400 FX off hwFailure swl -- -- -- -- fc9/48 1 E on hwFailure swl -- -- 57 --
Feilkoden vises i modulens interne unntakslogg som nedenfor:
`show module internal exceptionlog module 9`
********* Exception info for module 9 ********
exception information --- exception instance 1 ----
Module Slot Number: 9
Device Id : 204
Device Name : F16 Generic Driver
Device Errorcode : 0xccc05600
Device ID : 204 (0xcc)
Device Instance : 05 (0x05)
Dev Type (HW/SW) : 06 (0x06)
ErrNum (devInfo) : 00 (0x00)
System Errorcode : 0x42b8001e fatal error
Error Type : FATAL error
PhyPortLayer : Fibre Channel
Port(s) Affected : fc9/41-48
Error Description : F16_PLDA_RETRY_MERR
DSAP : 0 (0x0)
Time : Mon Jan 6 22:22:32 2025
(Ticks: 677CAC08 jiffies)
En tilbakestilling av modulen vises i Vis logging NVRAM:
`show logging nvram` 2025 Jan 6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600) 2025 Jan 6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE
`show logging log` 2025 Jan 6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600) 2025 Jan 6 22:22:32 WTXA19710H15 %PORT-CHANNEL-5-PORT_DOWN: port-channel57: fc9/48 is down 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/48 is down (Hardware Failure) port-channel57 ISL to WTXA19710C02 fc7/22 2025 Jan 6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/47 is down (Hardware Failure) ltx15brwccas01_h0 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/46 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/45 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/44 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/43 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/42 is down (Hardware Failure) ltx14brwccas02_h0 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/41 is down (Hardware Failure) ltx14brwccas01_h0
Cause
Den DEV_F16_CMN feilen på en svitsj i Cisco MDS 9000-serien indikerer vanligvis et maskinvareproblem relatert til F16 ASIC. Denne feilen fører ofte til at modulen starter på nytt på grunn av en uopprettelig ECC-feil (Multi-bit Error-Correcting Code).
Resolution
Den eneste måten å gjenopprette et grensesnitt fra hw_Failure er å forstyrre modulen på nytt.
#reload module x
Hvis grensesnittene er i en midlertidig maskinvarefeil, kan statusen gjenopprettes ved å laste modulen på nytt. Hvis grensesnittene har en permanent maskinvarefeil, fortsett med modulutskifting.
ADVARSEL: Aktiviteten er forstyrrende og bør utføres i vedlikeholdsvinduet.
Additional Information
SR #203555104
Affected Products
Connectrix MDS-Series HardwareArticle Properties
Article Number: 000271449
Article Type: Solution
Last Modified: 03 Feb 2025
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.