NetWorker: Incorrect Status and Size for Second Clone Copy in NMC

Summary: In NetWorker 19.10, the size and completion status of a second clone copy (Data Domain clone to tape) may display incorrectly in NetWorker Management Console (NMC). This occurs when the backup saveset spans multiple tape volumes. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • In NMC, the size of data cloned to tape appears incorrect
  • The original backup and the first clone to Data Domain display correct sizes in both NMC and mminfo
  • The second clone copy (DD to tape) shows:
    • Incorrect size values
    • Incorrect completion percentage

Cause

When a backup saveset spans more than one tape volume:

  • The cloning session starts with the first tape volume and then switches to the second
  • After completion:
    • The second session part reports the entire session size
    • The first session part retains a partial size
  • This duplication causes gstd to miscalculate the total size, resulting in incorrect completion percentage and size reporting in NMC

Resolution

  • This issue is tracked under Bug ID: NETWORKER-113140.
  • A fix is in the upcoming NetWorker release scheduled for the end of May 2025
  • Until the fix is applied:
    • The incorrect size/status is a display issue only; the clone data integrity is not affected
    • No manual workaround is required

Additional Information

  • Applies to NetWorker 19.10 and environments using Data Domain cloning to tape.
  • Verify actual clone size using mminfo for accurate reporting.
  • Monitor Dell release notes for the patch availability.

Products

NetWorker Family
Article Properties
Article Number: 000303777
Article Type: Solution
Last Modified: 25 Nov 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.