PowerEdge: Storage Components may Not be Displayed in iDRAC9 after Firmware Update
Summary: Storage components may not be displayed, or the status may appear as Unknown after upgrading iDRAC9 firmware to version 7.20.60.50 or 7.20.70.50.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The Lifecycle Controllers may log CTL138 and CTL139 errors at periodic intervals.
Cause
This issue usually occurs when external storage is connected to a Dell HBA355e adapter.
Resolution
To work around this issue, do the following.
- SSH to the iDRAC
- Run command
racadm set system.storage.LimitExternalHBATopology Enabled - Power cycle the server
Dell engineering is aware of this issue, and a fix is available in an upcoming iDRAC firmware version.