PowerScale: rpcbind Fails During Update if Using a Custom sysctl Value

Summary: "rpcbind" fails to start correctly during upgrades to specific OneFS versions if a custom value is set for "kern.ipc.somaxconn."

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

After upgrading to one of the following OneFS versions:

  • 9.7.1.3
  • 9.10.0.0

Client access is interrupted across all protocols, and running isi auth commands on the cluster cause the following error to appear:

p970-1# isi auth users list
Unable to connect to authentication daemon.  Please wait until authentication daemon has restarted and retry.

Messages in /var/log/messages indicating a failure to connect to the Remote Procedure Call (RPC) server:

2024-11-25T14:59:51.084340+00:00 <1.3> p970-1(id1) isi_celog_capture[4169]: drive_d_connect: Failed to connect to RPC server at 127.0.0.1 (errno=Invalid argument, rpc clnt_stat=15); retrying 2 of 3.

Cause

An issue in the logic that evaluated this setting in the two impacted versions of OneFS causes this issue. It is addressed in all other versions.

Resolution

This issue can be avoided if addressed before upgrading to an impacted OneFS version. If the cluster is already impacted, there are recovery steps as well.

Before Upgrade

Check for a custom value using the script below:

sys_files="/etc/mcp/templates/sysctl.conf
/etc/mcp/override/sysctl.conf
/etc/local/sysctl.conf";

while read -r file; do
  grep "somaxconn" "$file" 2>/dev/null
  done <<<"$sys_files"

If there is output; write down the value (512 is common), then use the following script to remove the entry:

sys_files="/etc/mcp/templates/sysctl.conf
/etc/mcp/override/sysctl.conf
/etc/local/sysctl.conf";

while read -r file; do
  sed -i bak "s/^kern.ipc.somaxconn.*//g" "$file" 2>/dev/null
  done <<<"$sys_files"

The upgrade can now be performed safely. After the upgrade, revert the setting to the previously written down value with the following command. Replace $val with the value noted.

isi_sysctl_cluster kern.ipc.somaxconn=$val

Then reboot nodes manually one at a time using whatever process if preferred.


After Impact

A reboot of the impacted nodes is required.

shutdown -r now