PowerStore: System health check detects a target port group issue that may affect mapping of an NVMeoF volume
Summary: Mapping an NVMeoF volume may lead to service disruption if there had been Add Appliances failures beforehand. The System Health check detects a target port group issue that may result in a service disruption while mapping an NVMeoF volume. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The System Check in the off-release health check package may identify an invalid target group id. This issue is described in KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
The issue is detected in the following scenarios:
The issue is detected in the following scenarios:
- Running a System Check using PowerStore Manager (UI) with the Run System Check option:
- Running the System Health Service Script (svc_health_check) using an SSH connection: Note: Output truncated for illustrative purposes.
| [SVC:cyc@ABCDEF-A ~]$ svc_health_check run -rhc target_port_group_id_check Name Location Status Description Target PortGroup Id Check node_a Failed Max value of LOCAL target_port_group_id is over the max threshold of 29. (KB000216953) |
Cause
After multiple add appliance failures, the target group id may be assigned a value outside of the valid range. This will impact the cluster when NVMEoF host mapping is being used.
Resolution
Contact technical support for assistance in resolving this issue. This should be resolved ASAP.
If not resolved, there is a high risk of the node may enter service mode or go down affecting the High Availability of the appliance.
This issue is planned to be resolved in a future PowerStoreOS release.
If not resolved, there is a high risk of the node may enter service mode or go down affecting the High Availability of the appliance.
This issue is planned to be resolved in a future PowerStoreOS release.
Additional Information
KB 000198084 PowerStore: How to use the System Check feature.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks is a public facing KB with a listing of all the health checks.
KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
KB 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks is a public facing KB with a listing of all the health checks.
KB 000216639 PowerStore: Mapping an NVMeoF volume may lead to service disruption on multi-appliance clusters.
Affected Products
PowerStoreArticle Properties
Article Number: 000216953
Article Type: Solution
Last Modified: 14 Jun 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.