PowerStore: System Health Checks detects an out-of-date System Manager Metadata on Disk (SYMMD) data on disks
Summary: This System Health Check (SHC) to detect if the latest System Manager Metadata on Disk (SYMMD) data is saved on disk. Two copies of SYMMD data are saved on disk. One copy is the same as what is in memory, the current running version. The other copy is from old SYMMD that was saved before NDU. During a disk firmware upgrade, the copy corresponding to the SYMMD in memory can be overwritten with the old copy. This check is to detect the above condition. It reads both copies from the disk, one of them has to be consistent with current running SYMMD. This check fails if both copies are wrong. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
System Health may display a System manager metadata on disk is invalid. (KB#000228110) message in one of the following scenarios:
- Running a System Check using PowerStore Manager (GUI) with the Run System Check option:
- Running the System Health Service Script (svc_health_check) using an SSH connection:
Note: Output truncated for illustrative purposes.
[BSC:cyc@8SP3DN3-A ~]$ svc_health_check run -rhc symmd_on_disk_check Name Location Status Description System Manager Metadata on Disk .. node_a Failed System manager metadata on disk is invalid. (KB#000228110) SUMMARY Status: Failed Passed: 0 Failed: 1 Total: 1
Note: Results may vary based on the node where the check failed.
The health check is an off-release SHC check that is contained in the Health Check thin package. See the Additional Info section of this article for information about the Health Check thin package.
Cause
Attempting to restart or shut down the System Manager (SYM) node under this condition may cause SYM to not start. This scenario may also trigger a Data Unavailability (DU) condition.
Resolution
To resolve this issue, contact technical support for assistance. Reference KB# 000228110 for expedited attention and resolution.
Additional Information
KB# 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
KB# 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.
Affected Products
PowerStoreArticle Properties
Article Number: 000228110
Article Type: Solution
Last Modified: 14 Jun 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.