PowerStore Alerts: System Reimage

Summary: -PowerStoreX Reimage Failed. -PowerStoreX Reimage Done and Hotfix Required.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution provided, check the technical support contact options.
SLN320845_en_US__1icon Note: Cannot find the information needed? Let us know using the feedback form at the bottom of this article.

Cause

The cause is mentioned in the Resolution section.

Resolution

Alert ID PLATFORM_SYSTEM_REIMAGE_FAILED
Description If a PowerStore appliance encounters serious issues like a corrupted partition system, root directory destroyed by accident, or primary m.2 disk failure. The reimage process could be kicked off to make the system back to the normal status. The reimage process will automatically restore the system partitions, reinstall the ESXi server if it is PowerStore X system, reinstall the CoreOS operation system and all docker images, and reapply the system configuration back to the system. The procedure is automatically applied. No manual operation is required.
But, if the reimage process fails in the middle, it might leave the system at the half-recovered situation. The critical alert is raised when required to manually fix the system.
Alert Text Node %(which) reimage (primary M.2) failed.
Error Code (0x00400302)
Resolution Cause
The system reimage encounter issues, and reimage is failed.

Solution
Contact technical support for assistance.
 

 

Alert ID PLATFORM_SYSTEM_REIMAGE_DONE_HOTFIX_REQUIRED
Description If a PowerStore appliance encounters serious issues, like a corrupted partition system, root directory destroyed by accident, or primary m.2 disk failure, the reimage process could be kicked off to restore the system back to the normal status. The reimage process will automatically restore the system partitions, reinstall the ESXi server if it is PowerStore X system, reinstall the CoreOS operation system and all docker images, and reapply the system configuration back to the system. The procedure is automatically applied. No manual operation is required.
If the system has hotfix applied to the system before reimage. The reimage process cannot apply the hotfix automatically. A manual process is required to reinstall the hotfix on the system after reimage.
Alert Text Hotfix was not able to be applied during node %(which) (primary M.2) reimage.
Error Code (0x00400303)
Resolution Cause
The system encountered an issue resulting in reimage being applied. The system has detected that a hotfix had previously been installed and requires manual reinstallation.

Solution
Contact Technical Support for assistance to reapply hotfixes.