Dell Unity: Erros FCP LPFC relatados em hosts com HBAs Emulex (corrigíveis pelo usuário)

Summary: Novos hosts que executam o driver ESX Emulex FC mais recente para números de modelo de HBA Emulex: LPe31000, LPe32000, LPe3500x, LPe3600x estão relatando erros FCP LPFC quando adicionados ao array unity. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Os registros do VMkernel são inundados com o seguinte erro:
 
WARNING: lpfc: lpfc_handle_fcp_rsp_err:4915: 0:(0):2757 Protocol failure detected during processing of FCP I/O op: tgt x2 lun x1 cmnd x28 rspInfo3 x2

2021-11-08T14:22:08.949Z cpu8:2098569)WARNING: lpfc: lpfc_handle_fcp_rsp_err:4939: 1:(0):2757 Protocol failure detected during processing of FCP I/O op: tgt x1 lun x0 cmnd x28 rspInfo3 x2


** Os comandos de leitura são rejeitados pelo array unity com RSP_CODE=0x2 indicando "FCP_CMND fields invalid"
** A falha nos comandos de leitura faz com que o caminho entre DEAD/Flapping

Severe performance issue é relatado.

Cause

  • O storage array Unity não lida corretamente com o valor diferente de zero no campo reservado (COMMAND REFERENCE NUMBER - Byte8) do comando FCP. 
  • Quando o FCP_CMND byte de carga útil 8 (COMMAND_REFERENCE_NUMBER) não for zero, o Unity rejeitará o comando com um FCP_RSP_CODE de 2, INVALID_FIELD.
  • Com base nas especificações FCP 4/5, o array de destino deve ignorar esse campo se ele não for compatível com ele.

Resolution

O Unity OE 5.2.0.0.5.173 contém a correção para esse problema.

Affected Products

Emulex Family of Adapters, Dell EMC Unity Family
Article Properties
Article Number: 000196094
Article Type: Solution
Last Modified: 16 Oct 2025
Version:  8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.