GDDR: ABENDs 0C4-04 and 0C4-10 and Error Message GDDM105E Occurring

Summary: ABENDS 0C4-04 and 0C4-10 are occurring in GDDRMAIN on DC1 and DC2. Error message GDDM105E occurs after ABEND 0C4-10 on DC2. DC2 is the Primary site.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

ABENDS 0C4-04 and 0C4-10 are occurring in GDDRMAIN on DC1 and DC2. Error message GDDM105E occurs after ABEND 0C4-10 on DC2. DC2 is the Primary site.

DC1:

IEA794I SVC DUMP HAS CAPTURED:  973                                   
DUMPID=001 REQUESTED BY JOB (GDDRMAIN)                                
DUMP TITLE=GDDRMCMD Abend                                             
IEA995I SYMPTOM DUMP OUTPUT  979                                      
SYSTEM COMPLETION CODE=0C4  REASON CODE=00000004                      
 TIME=12.28.05  SEQ=00055  CPU=0000  ASID=0049                        
 PSW AT TIME OF ERROR  078C2000   9F6518E4  ILC 6  INTC 04            
   ACTIVE MODULE           ADDRESS=00000000_1F600F78  OFFSET=0005096C 
   NAME=GDDRMAIN                                                      
   DATA AT PSW  1F6518DE - D2451001  1000D213  1031DB39               
   GR 0: 1F726FDE   1: 1F726FDE                                       
      2: 1F91B358   3: 009ECD64                                       
      4: 00000000   5: 00F95280                                       
      6: 009D1FC8   7: 00000E00                                       
      8: 1F63DDD8   9: 1F920F8D                                       
      A: 1D898180   B: 1F63D120                                       
      C: 9F622878   D: 1F91FED0                                       
      E: 1F920C57   F: 9F651820                                       
 END OF SYMPTOM DUMP                                                                                

DC2:

IEA995I SYMPTOM DUMP OUTPUT  371                                      
SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010                      
 TIME=13.30.42  SEQ=00050  CPU=0000  ASID=004F                        
 PSW AT TIME OF ERROR  478C0000   9F75BDCC  ILC 4  INTC 10            
   ACTIVE MODULE           ADDRESS=00000000_1F74DC98  OFFSET=0000E134 
   NAME=GDDRWMGR                                                      
   DATA AT PSW  1F75BDC6 - C37858A0  7058BF9F  A0349A0F               
   GR 0: 00000010   1: 1F91E4C0                                       
      2: 1F693238   3: 00000000                                       
      4: 1F91E4C0   5: 1F91E758                                       
      6: 1F91EB48   7: 1F693000                                       
      8: 00000000   9: 00000000                                       
      A: 60606060   B: 00000000                                       
      C: 9F75BBA4   D: 1F6932C8                                       
      E: 00FD6320   F: 9F75BBA4                                       
 END OF SYMPTOM DUMP                

DC2 Error Message:

GDDM105E Unable to obtain work control block

Error message occurs hours later if WORKMGR is restarted. This error message posts repeatedly.

Cause

The S0C4-10 or S0C4-04 abends are caused by a buffer overlay in the work area of the Geographically Dispersed Disaster Restart (GDDR) Work Manager (GDDRWMGR). The Abends may occur in GDDRMCMD at the time of the buffer overlay or after the fact in GDDRWMGR.

Resolution

Permanent Fix: For GDDR 6.0, Program Temporary Fix (PTF) GD60020 is available to address the issue. It is available to download from Dell Online Support.

Affected Products

Geographically Dispersed Disaster Restart (GDDR)