VNX 整合:VNX-FILE 複製健全狀況檢查程式-使用者可更正

Summary: 本文探討如何在 VNX-FILE 環境中執行健全狀況檢查。此程式會在本機和遠端執行環境中所有控制站的健全狀況檢查。此計畫著重于複製相關資訊。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

  1. 將檔案上傳至 VNX-FILE 控制站。上傳後,請使用下列命令解壓縮檔案:  
[nasadmin@CS0 tmp]$ tar -xvf KB000479575-IPRep_Health_Check_V1.3.tar
Replication_Health_Check.pl
[nasadmin@CS0 tmp]$ ls -al
-rw-rw-r-- 1 nasadmin nasadmin 112640 Aug 15 08:01 KB000479575-IPRep_Health_Check_V1.3.tar
-rwxrwxr-x 1 nasadmin nasadmin 102131 Aug 15 07:50 Replication_Health_Check.pl
  1. 使用下列命令確認 MD5SUM 相符:  
[nasadmin@CS0 tmp]$ md5sum *
d621f3e53770a5b6e1d61590562eb718  KB000479575-IPRep_Health_Check_V1.3.tar
8859de64706171fc19e1d245e7b80670  Replication_Health_Check.pl
[nasadmin@CS0 tmp]$

如何啟動健全狀況檢查
  1. 執行下列命令以啟動健全狀況檢查:  
[nasadmin@CS0 tmp]$ ./Replication_Health_Check.pl -full

此計畫需要幾分鐘的時間才能完成。畫面上會顯示摘要輸出,以確認其正在進行中。程式完成後,請依照如何解決任何未發現的問題的指示操作。

除了螢幕輸出之外,還有一個詳細記錄檔會建立並儲存在控制站本機。如需任何錯誤的詳細資訊,請參閱記錄檔。檔案名和位置會有所不同,且會在程式執行時顯示。

新增新專案,即可在系統目前的複寫會話中檢視「即時系統效能輸送量」摘要。這是為了協助顯示「高階」系統效能統計資料。

Additional Information

方案使用
KBA 479575 - VNX-FILE Replication Health Check
This Health Check program will review local and remote nas_replicate sessions.
This program is designed to be executed on the EMC VNX-FILE control station.

########################################################################
  Usage: ./Replication_Health_Check.pl [ -full | -cs | -inter | -repl | -fs | -debug ]
         -full   : Recommended value, runs checks against all configurations
         -cs    : Validates Control Station (CS-CS) communication
         -inter : Validates local and remote interconnects (This is time consuming)
         -repl  : Reviews Replication related statistics
         -fs     : Reviews File System and CKPT settings
         -perf  : Display Replication Performance Statistics (not a health check)
         -debug : Captures FULL debug information, only use if filing a bug
             EXAMPLE ./Replication_Health_Check.pl -cs
             EXAMPLE ./Replication_Health_Check.pl -full
########################################################################

[nasadmin@CS0 tmp]$

Affected Products

VNX VG10, VNX VG2, VNX VG8, VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5800, VNX7500, VNX7600, VNX8000
Article Properties
Article Number: 000009093
Article Type: How To
Last Modified: 03 Jan 2024
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.