PowerStore: Filesystem usage capacity alerts disabled after upgrade.

Resumen: After upgrading an appliance from PowerStoreOS 2.1 (or earlier) to PowerStoreOS 3.0 (or later version), Filesystems that were created before the upgrade will not trigger FS's usage capacity alerts. The Health Check thin package has a check to detect this condition. ...

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

After upgrading an appliance from PowerStoreOS 2.1 (or earlier) to PowerStoreOS 3.0 (or later version), Filesystems that were created before the upgrade will no longer trigger FS's usage capacity alerts.

The Health Check thin package has a check to detect this condition.

Example screenshot for System Check:
image.png


Example output for System Health Service Script (svc_health_check) using an SSH connection:
$ svc_health_check run -rhc sdnas_capacity_alert_check
Name                               Location  Status     Description
File System Capacity Alert Check   node_a    Passed
File System Capacity Alert Check   node_b    Failed     Found file systems without capacity alert capability. (KB#000217839)
 
 
SUMMARY Status: Failed
   Passed:      1
   Failed:      1
   Total:       2
 
 

Causa

Due to a change in SDNAS in PowerStoreOS 3.0, the space alert thresholds settings are reconfigured. A new capability to have per-filesystem thresholds is introduced and during the upgrade are not properly initialized to the proper defaults.

In case the appliance runs out of space, all Filesystems that were created in 2.1 or earlier versions, before the upgrade to 3.0.x or later, will no longer trigger Filesystems usage capacity alerts.



Resolución

The issue is fixed in 3.6.1.0.

To resolve this issue if it has occurred, upgrade to 3.6.1.0 code or later. 
If system was upgraded from version 2.1.x (and earlier versions) to a version prior to 3.6.1.0 and no alert was received for capacity issues, upgrade to 3.6.1.0 or later. If upgrade cannot be performed to 3.6.1.0 or later, contact support to verify the issue and for a fix to be applied. Reference this KB Article for expedited assistance. 

Productos afectados

PowerStore
Propiedades del artículo
Número del artículo: 000217839
Tipo de artículo: Solution
Última modificación: 14 jun 2025
Versión:  8
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.