Isilon: Node Firmware updates immediately error on Generation 6 nodes with a missing/failed M2 Vault Card
Resumen: Isilon: Node Firmware updates immediately error on Generation 6 nodes with a missing/failed M2 Vault Card
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
Generation 6 nodes require use of an M.2 Vault Card in each node to perform node firmware updates. If the M.2 Vault Card is missing or has failed, attempts to perform node firmware updates on those nodes will encounter an error.
In addition to errors in the upgrade view, the log file, /var/log/isi_firmware.log, on the node where the error was encountered will have a line which includes "no such object ada0" similar to the following:
2020-01-01 04:54:25,169 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,170 INFO [11111] : FW action: toggle_debug: off
2020-01-01 04:54:25,241 INFO [11111] : FW action: Updating Node 1
2020-01-01 04:54:25,263 INFO [11111] : Updating device EPssp_infinity
2020-01-01 04:54:25,263 INFO [22222] : <rpc> EPssp_infinity(EPssp_infinity): version=02.50 target=02.81
2020-01-01 04:54:25,264 INFO [11111] : Updating Firmware EPssp_infinity - old: 02.50 new : 02.81
2020-01-01 04:54:25,526 ERROR [11111] : Node 1: 'no such object ada0'
2020-01-01 04:54:25,565 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,565 INFO [11111] : FW action: toggle_debug: offCausa
missing vault card
Resolución
When encountered, the M.2 Vault Card on the node should be replaced.
Información adicional
The Isilon On-Cluster Analysis health check script includes a check to identify when the M.2 Vault Card is missing or has exceeded it's SMART status threshold and may report results similar to the following:
Vault Card FAIL FAIL: The vault card located at ada0 in the following Generation 6 nodes are not reporting in the output of camcontrol devlist: 1 FAIL: The vault card located at ada0 in the following Generation 6 nodes are reporting SMART status is threshold exceeded: 1
To run only the check for the Vault Card, use the following additional argument when running the Isilon On-Cluster Analysis tool: --run=checkVaultCard
Productos afectados
Isilon Gen6Productos
Isilon Gen6Propiedades del artículo
Número del artículo: 000082048
Tipo de artículo: Solution
Última modificación: 18 abr 2026
Versión: 5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.