MFE SCF: 씬 모니터링 매개변수 ACTION=MESSAGE(MESSAGE)가 코딩될 때 EMCP020E EXTRANEOUS DATA IN COMMAND이 반환됩니다.

Resumen: PARM_VERIFY=YES를 사용한 MESSAGE 매개변수의 잘못된 확인

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

When the PARM_VERIFY=YES parameter is specified in the ResourcePak Base initialization file, the incorrect EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ")"  message is displayed. 
예:
SCF0301I SCF.THN.03.LIST = ACTION=MESSAGE(MESSAGE)
SCF0313I SCF.THN.03.LIST=ACTION=MESSAGE(MESSAGE)
EMCP010E *
EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )
SCF0301I SCF.THN.03.LIST = FREQUENCY=REPEAT
SCF0301I SCF.THN.04.LIST = PERCENT=(99,100)
SCF0301I SCF.THN.04.LIST = DURATION=60
SCF0301I SCF.THN.04.LIST = ACTION=MESSAGE(MESSAGE)
SCF0313I SCF.THN.04.LIST=ACTION=MESSAGE(MESSAGE)
EMCP010E *
EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )
SCF0301I SCF.THN.04.LIST = FREQUENCY=REPEAT                      

Causa

이는 소프트웨어 문제로 인해 발생합니다.

Resolución

영구 수정:
  • Mainframe Enablers 8.5의 경우 문제를 해결하기 위해 PTF SF85111이 개발되었습니다. Dell 온라인 지원에서 다운로드할 수 있습니다.
  • Mainframe Enablers 8.4의 경우 문제를 해결하기 위해 PTF SF84158이 개발되었습니다. Dell 온라인 지원에서 다운로드할 수 있습니다.

Información adicional

EMCP020E
명령의 불필요한 데이터 FOUND: 값
원인
입력 데이터 스트림을 구문 분석하는 동안 구문 오류가 감지되고 불필요한 데이터가 발견되었습니다.
작업
입력 데이터 스트림을 수정합니다.

PTF 커버 참고 사항:
 
++PTF(SF85111) REWORK(2022038) .                               
++VER(Z038) FMID(SSCF850)                                     
      PRE(                                                    
          SF85002 SF85042                                     
          )                                                    
   /*                                                         
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):                                     
* ------------------------------------------------------------
* USERS AFFECTED: Users of the THN Monitor                    
* PROBLEM DESCRIPTION: Incorrect verification of the MESSAGE  
*                      parameter with PARM_VERIFY=YES         
* DESCRIPTION DETAIL:                                         
*                                                             
* When the PARM_VERIFY=YES parameter is specified in the SCF  
* initialization file, the incorrect                          
* EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )               
* message is displayed.                                       
*                                                             
* PROBLEM RESOLUTION:                                         
*                                                             
* The code has been updated to correctly verify syntax of the 
* MESSAGE parameter.                                          
*                                                             
* MODULES: ESFINI                                             
*          SCFLIND                                            
*                                                             
* ------------------------------------------------------------
* SF85111 7 Feb 2022 15:15:32                                 
* ------------------------------------------------------------

Productos afectados

Mainframe Enablers
Propiedades del artículo
Número del artículo: 000196982
Tipo de artículo: Solution
Última modificación: 16 jun 2023
Versión:  5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.