PowerProtect Data Manager: Kubernetes Cluster Discovery mislyktes – IO-unntak under neste metode (strømmen ble tilbakestilt)
Resumen: PowerProtect Data Manager Kubernetes Cluster Discovery mislyktes – IO-unntak under neste metode (strømmen ble tilbakestilt).
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
PowerProtect Data Manager Kubernetes Cluster Discovery mislyktes.
Følgende feil er observert i cndm.log:
Følgende feil er observert i cndm.log:
2023-03-23T03:32:43.470Z ERROR [] [https-jsse-nio-127.0.0.1-8461-exec-3] [][][][TRACE_ID:9a9664af3ecde3e2;JOB_ID:9d8702e6e8798fea][] [c.e.b.c.d.s.CndmDiscoveryService.start(84)] - discovery task failed com.emc.brs.cndm.error.InternalServerErrorException: java.lang.RuntimeException: IO Exception during next method. Caused by: java.lang.RuntimeException: IO Exception during next method. Caused by: okhttp3.internal.http2.StreamResetException: stream was reset: INTERNAL_ERROR
Causa
Produktet fungerer som det skal.
Resolución
I ett tilfelle hvor dette observeres, finnes det en Nginx-server mellom PowerProtect Data Manager og K8s-klyngen.
Endre følgende innstillinger i Nginx-konfigurasjonsfilen /etc/nginx/default.d/server.conf
proxy_redirect av;
proxy_buffering av;
PPDM Kubernetes Cluster Discovery er greit etter denne endringen.
Endre følgende innstillinger i Nginx-konfigurasjonsfilen /etc/nginx/default.d/server.conf
proxy_redirect av;
proxy_buffering av;
PPDM Kubernetes Cluster Discovery er greit etter denne endringen.
Productos afectados
PowerProtect Data ManagerPropiedades del artículo
Número del artículo: 000212870
Tipo de artículo: Solution
Última modificación: 18 may 2023
Versión: 2
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.