Connectrix Cisco MDS-Series : XBAR-2-XBAR_MONITOR_INTERNAL_CRC_ERR : Module-X détecte une erreur CRC au niveau du moteur Qress
Résumé: XBAR-2-XBAR_MONITOR_INTERNAL_CRC_ERR connecté à un module FC
Symptômes
Journal de journalisation :2025 Jan 3 05:00:03.406 MDS %XBAR-2-XBAR_MONITOR_INTERNAL_CRC_ERR: Module-2 detects CRC error at Ingress Qengine <SNIP>2025 Jan 17 19:00:12.182 MDS %XBAR-2-XBAR_MONITOR_INTERNAL_CRC_ERR: Module-2 detects CRC error at Ingress Qengine
`show system internal xbar event-history errors`<SNIP>2025 Jan 17 19:00:12.182392: E_DEBUG [102] xbm_crc_err_handle_stage1_crc_error(3386): Module-2 detects crc_error:18 at Ingress Qengine so putting in failure state crc_flag 7<SNIP>2025 Jan 17 18:59:07.481841: E_DEBUG [102] xbm_crc_err_handle_stage1_crc_error(3386): Module-2 detects crc_error:19 at Ingress Qengine so putting in failure state crc_flag 7<SNIP>52025 Jan 17 18:58:06.664440: E_DEBUG [102] xbm_crc_err_handle_stage1_crc_error(3386): Module-2 detects crc_error:30 at Ingress Qengine so putting in failure state crc_flag 7
Show hardware internal errors all slot 2=======
|--------------------------------------------------------------------------------------------------------|| Device:F16 Que Driver Role:QUE Mod: 2 || Last cleared @ | Device Statistics Category :: ERROR|--------------------------------------------------------------------------------------------------------|
Instance:5Cntr Name Value Ports------ ---------------------------------------------------------------------- --------------- ----------39 F16_IPA_IPA0_CNT_BAD_CRC 0000000026913029 41-44 -40 F16_IPA_IPA0_CNT_CORRUPT 0000000026913029 41-44 -6002 F16_IPA_INT_CFG_PAR_ERR 0000000000000001 41-48 -6023 F16_IPA0_INT_ORIG_CRC_BAD 0000000012770240 41-44 -
Cause
Cause:
Le module FC du logement 2 est à l’origine des erreurs CRC internes .`show module`Mod Ports Module-Type Model Status--- ----- ----------------------------------- ------------------ ----------1 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok2 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok <-----------------3 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok4 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok5 0 Supervisor Module-3 DS-X97-SF1-K9 active *6 0 Supervisor Module-3 DS-X97-SF1-K9 ha-standby7 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok8 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok9 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok10 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok
Résolution
Résolution:
Remettez en place la carte de ligne dans le logement 2
. Après un remplacement, effacez tous les compteurs de commutateurs comme suit :
-debug system internal clear-counters all-clear counters interface all snmp-clear counters interface all-clear statistics module-all device all
Après avoir effacé les compteurs, recherchez d’autres erreurs, telles que des CRC d’entrée sur toutes les interfaces associées à la carte de ligne remplacée.